Skip to main content
Home › Commercial PoE Switches › NSW2010-10T-POE-S-IN

NSW2010-10T-POE-S-IN

Uniview · PoE Switch
Unmanaged Fast Ethernet PoE Switch · 10×10/100M (8 PoE · 96W) + 2 Uplink
Project-Based Pricing
Volume & combo discounts — get your quote
In-stock models: 3 days to your forwarder's warehouse in China after payment · Out-of-stock: 7–15 working days · then air 5–10 days or sea 25–45 days to your port
Get Best Price on WhatsAppRequest a quote ↓

Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA

Not sure about the PoE budget? Size it with the calculator →

Need the PDF datasheet? Get it on WhatsApp →
How to get a better price
Volume DiscountOrder 50+ pcs of this model
CONTACT US
Project Combo DiscountMix any categories & models storewide in one order — no quantity limit
BIGGER
Verified Project DiscountDistributor, integrator or end user with a real project? Send the BOQ — project pricing plus free system design. Partner projects are protected: we never quote your end customer behind you
BIGGEST
All discounts are quoted personally — message me on WhatsApp ↑
◆8 PoE Ports
◆PoE 96 W
◆2 Gbps
◆EXTEND 250 m
◆Fanless

Overview

The NSW2010-10T-POE-S-IN is an unmanaged Fast Ethernet PoE switch with 10 × 10/100Mbps RJ45 ports — 8 PoE-enabled downlink ports plus 2 uplink ports — built for plug-and-play CCTV deployments. It delivers a 96 W total PoE power budget (30 W max per port, Mode A pinout: 1/2+, 3/6-) over a 2 Gbps switching fabric with 1.49 Mpps forwarding, a 768K bit packet buffer and a 2K MAC address table. A fanless 200×118×44 mm metal housing (0.61 kg) runs from -10°C to 50°C and switches between Normal, EXTEND (250 m surveillance reach) and VLAN working modes via a front-panel DIP switch — no management software required.

Is This the Right Fit?

Six real deployment scenarios matched to this model's actual datasheet specifications.

Plug-and-Play Small-Site CCTVNo CLI or web login — flip the front-panel DIP switch to Normal, EXTEND or VLAN mode and start powering cameras in minutes; built for shops, offices and small guard posts.
Warehouse & Retail Camera AggregationThe 96 W PoE budget covers eight typical fixed cameras (10–13 W each) with headroom, and any single port can still feed a 30 W device — one box handles power and uplink for a small camera run.
250 m Reach Without New CablingEXTEND mode stretches PoE and data past the standard 100 m Ethernet limit to 250 m — reach a distant gate or lot camera on this switch instead of adding a repeater or media converter.
Fanless Desk & Rack-Shelf Install0 cooling fans keep the 200×118×44 mm metal case silent — sits on a desk, shelf or beside a DVR/NVR without fan noise or the need for forced-air clearance.
Isolated Guest/Kiosk DownlinksVLAN (secure) mode restricts downlink ports to talk only with the uplink port — a simple way to keep camera or kiosk ports from seeing each other's traffic without configuring real VLANs.
Fast Field Installs, Any Cable OrientationAuto MDI/MDIX means installers can use any patch or crossover cable on any port — no rewiring or cable swaps needed during a rushed on-site install.
Not a good fit if:
  • Unmanaged — no Web/CLI/SNMP access, VLAN tagging or per-port traffic statistics; choose a managed switch if you need remote configuration or monitoring.
  • Fast Ethernet only (10/100Mbps, no Gigabit) — for 4K or multi-stream camera backbones and NVR uplinks, choose a Gigabit PoE switch instead.
  • 30 W max per port and 96 W total budget — not all 8 PoE ports can run at full 30 W simultaneously (8×30 W = 240 W > 96 W budget), and 802.3bt heated PTZ domes (60–90 W) need a bt-capable switch or midspan injector.

Key Features

  • 10 × 10/100Mbps RJ45 ports, including 8 PoE-enabled downlink ports
  • 96 W total PoE budget, up to 30 W per port, Mode A pinout (1/2+, 3/6-)
  • IEEE 802.3x full-duplex flow control and half-duplex back-pressure congestion control
  • Auto MDI/MDIX port flip — connects with any straight-through or crossover cable
  • Automatic power adaptation to connected PoE devices
  • Front-panel PWR/Link/DIP indicators for status monitoring and fault analysis
  • Three working modes via DIP switch: Normal, EXTEND (250 m) and VLAN (secure downlink)

Specifications

IEEE Standards

IEEE802.3 / 802.3u10/100Base Ethernet
IEEE802.3xFlow control (full-duplex) & back-pressure (half-duplex)

Ports

Total ports10 × 10/100Mbps RJ45
PoE ports8 (of 10)
Uplink ports2 × 10/100Mbps RJ45
MDI/MDIXAuto (auto flip)

Performance

Switching capacity2 Gbps
Forwarding rate1.49 Mpps
Packet buffer768K bit
MAC address table2K

PoE

Total budget96 W
Per port30 W
Pin modeMode A: 1/2(+), 3/6(-)

Power & Environment

Max. power consumption101 W
CoolingFanless (0 fans)
Operating temp.-10°C ~ 50°C (14°F ~ 122°F)
Humidity10% ~ 90% non-condensing
Dimensions (W×D×H)200 × 118 × 44 mm
Package dimensions245 × 190 × 60 mm
Weight0.61 kg
IndicatorsPWR · SW (DIP) · 1-6 Green (Link&Data)
Working modesNormal / EXTEND (250 m) / VLAN — via DIP switch

Models & Ordering

ModelProduct DescriptionPrice
NSW2010-10T-POE-S-INUnmanaged Fast Ethernet PoE switch — 10 × 10/100Mbps RJ45 (8 PoE ports, 96 W total budget, 30 W/port max, Mode A), fanless metal housing, -10°C to 50°C.✆ WhatsApp

Single fixed-configuration SKU — no variant options for this model.

Dimensions

NSW2010-10T-POE-S-IN dimension drawing, 200 x 118 x 44 mm
unit: mm
Project Bundles WelcomeCameras + NVR + switches + cabling quoted as one bundle · Free full-project BOM review.
Talk to an engineer →

Who uses it, where it goes and how to install it

Written for the NSW2010-10T-POE-S-IN from its own datasheet: unmanaged 10-port Fast Ethernet switch, 8 PoE ports, 96 W budget (30 W per port, Mode A), Normal/EXTEND 250 m/VLAN modes, fanless, -10 °C to 50 °C.

Who it is for

  • Installers fitting an 8-camera system — 8 PoE ports and 96 W power eight fixed cameras from one box next to an 8-channel NVR, with 2 more ports for the NVR and the router.
  • Shops, offices and small warehouses — Fanless metal case (0.61 kg, 200 × 118 × 44 mm) that sits silently on a shelf in an indoor room between -10 °C and 50 °C.
  • Sites with one or two distant cameras — EXTEND mode reaches up to 250 m, enough for a gate or car park camera that is past the 100 m Ethernet limit, without a repeater.
  • Hotels, kiosks and shared buildings — VLAN (secure) mode lets the downlink ports talk only to the uplink, so a device plugged into one camera port cannot reach the others.

Where and how to install

  • Indoors only, with air around it — The rating is -10 °C to 50 °C and 10–90% humidity without condensation, and the case is cooled only by its metal body. Do not put it in an outdoor box, on top of a hot NVR or in a closed cupboard; leave a few centimetres free on each side.
  • Power and UPS — Maximum power is 101 W with the full 96 W of PoE. The datasheet does not say whether the supply is built in or an external adapter, so confirm this with us, and include the 101 W in the UPS size together with the NVR.
  • Cable runs — Normal mode: up to 100 m of Cat5e/Cat6 per camera. EXTEND mode: up to 250 m; the datasheet does not give the link speed in this mode, and such modes normally lower it, so keep those cameras at a modest bitrate. Use solid pure-copper cable for long PoE runs.
  • Outdoor cameras need surge protection — No surge rating is listed for this switch. Where cables run to outdoor poles or walls, add an Ethernet surge protector near the switch and earth it, and earth the rack or shelf the switch stands on.
  • Mind the 100 Mbps uplink — All 10 ports are 10/100 Mbps, including the 2 uplinks, so everything going to the NVR shares 100 Mbps. Keep the total at about 70–80 Mbps, for example 8 cameras at 8 Mbps use 64 Mbps; higher bitrates need a gigabit-uplink switch.

PoE budget: NSW2010-10T-POE-S-IN next to the NSW2020-10T-POE-IN

Both have 8 PoE ports plus 2 uplinks at 10/100 Mbps and up to 30 W per port. The NSW2010-10T-POE-S-IN has the larger budget (96 W against 88 W), a wider temperature range and a VLAN isolation mode; the NSW2020-10T-POE-IN is smaller and lighter.

NSW2010-10T-POE-S-IN (this page)NSW2020-10T-POE-IN
PoE ports / uplinks8 / 2, all 10/100 Mbps8 / 2, all 10/100 Mbps
PoE budget / per port / pinout96 W / 30 W / Mode A88 W / 30 W / Mode B
4 MP IR cameras at 6 W8 (48 W)8 (48 W)
Mini PTZ at 13 W7 (91 W)6 (78 W)
IR PTZ at 25 W3 (75 W)3 (75 W)
Switching capacity2 Gbps2 Gbps
Working modesNormal / EXTEND 250 m / VLANNormal / EXTEND 250 m
Operating temperature-10 °C to 50 °C0 °C to 45 °C
Size / weight200 × 118 × 44 mm / 0.61 kg171 × 103 × 25 mm / 0.29 kg
Max. power consumption101 W94 W
  • Eight fixed cameras on an 8-channel NVR: either switch works; pick the NSW2010-10T-POE-S-IN if the room gets hotter than 45 °C or you want VLAN isolation.
  • Several mini PTZ cameras: the 96 W budget runs 7 at 13 W, one more than an 88 W switch.
  • Outdoor cabinet or heavy frost: neither is rated for it; use the industrial ISW2000-8T2GP-POE-IN (-30 °C to 65 °C).

Camera draws (6 W, 13 W, 25 W) are typical assumptions; use the maximum power from each camera's datasheet. NSW2020-10T-POE-IN figures are from its own Uniview datasheet.

8-Port PoE Switch FAQ — NSW2010-10T-POE-S-IN

How many cameras can the NSW2010-10T-POE-S-IN power?
8 of its 10 ports are PoE downlinks sharing a 96 W budget — 12 W average per camera with all eight connected. Typical fixed IP cameras draw 4–12 W, so a full 8-camera system fits, and one port can push up to 30 W for a PTZ. The other 2 ports are uplinks.
How do I reach a camera 250 m away?
Flip the front-panel DIP switch to EXTEND mode: the PoE ports then carry data and power up to 250 m for surveillance runs, with no repeater in between. Normal and VLAN modes are on the same DIP switch, so one unmanaged switch covers three deployment cases without any software.
Is it silent enough for offices and small shops?
Yes — it is fanless (zero fans), so there is no moving part and no noise. The 200 × 118 × 44 mm metal housing weighs 0.61 kg, operates from -10 to 50 °C at 10–90% non-condensing humidity, and sits on a shelf or inside a small CCTV cabinet without ventilation planning.
Which PoE pinout does it use and how much power does it draw?
PoE is delivered in Mode A pinout — pins 1/2 positive, 3/6 negative — which suits standard IP cameras. The PoE budget is 96 W with 30 W maximum per port, and total switch consumption tops out at 101 W, so size the supply circuit for about 101 W at full camera load.
Is the bandwidth enough for 8 camera streams?
Yes. The 10 × 10/100 Mbps ports ride on a 2 Gbps switching fabric at 1.49 Mpps, with a 768K bit packet buffer and 2K MAC table. Eight camera streams typically run a few Mbps each, so the fabric and the two 10/100 uplink ports to the NVR have clear headroom.
Will the NSW2010-10T-POE-S-IN power Hikvision, Dahua or other non-Uniview cameras?
Usually yes. The switch detects the connected device and powers it automatically, sends power on pins 1/2 and 3/6 (Mode A), and gives up to 30 W per port; standard 802.3af/at cameras of any brand accept Mode A. Note that the datasheet's standards list shows IEEE 802.3, 802.3u and 802.3x and does not name 802.3af/at, so tell us the camera models and we confirm before you order. Passive 12 V or 24 V PoE devices are not supported this way.
Can I mix PTZ and fixed cameras on the NSW2010-10T-POE-S-IN?
Yes, as long as each camera stays at or below 30 W and the total stays within 96 W. For example, 2 IR PTZ cameras at 25 W plus 6 fixed cameras at 6 W use 86 W, which fits; 3 PTZ at 25 W plus 5 fixed at 6 W would be 105 W, which does not. Add up the maximum power from each camera's datasheet, since IR and heaters raise the draw at night.
Where do I connect the NVR on the NSW2010-10T-POE-S-IN, and what changes in VLAN mode?
Connect the NVR to one of the 2 uplink ports and the router or next switch to the other. In Normal mode all ports talk to each other, so placement matters less; in VLAN (secure) mode the downlink ports can talk only to the uplink ports, so an NVR on a PoE port would lose the cameras. VLAN mode also stops cameras from reaching each other, which is what you want on a shared or public site.
Can I cascade two NSW2010-10T-POE-S-IN switches for 16 cameras?
Yes, uplink to uplink, but the link between them and the link to the NVR are 100 Mbps. 16 cameras at 4 Mbps use 64 Mbps and fit; 16 at 8 Mbps would be 128 Mbps and do not. A better layout is to connect each switch on its own uplink to a gigabit switch or to the NVR's own ports, and never connect the two switches with a second cable, which makes a loop.
Can the NSW2010-10T-POE-S-IN go in an outdoor box or a hot plant room?
Not as a rule. It is rated -10 °C to 50 °C and 10–90% humidity without condensation, and no surge rating is listed, which suits an indoor room or rack. A sealed box in the sun easily goes above 50 °C. For outdoor cabinets use the industrial ISW2000-8T2GP-POE-IN, rated -30 °C to 65 °C with ±2/4 kV surge protection.

Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.

Request a quote for this product

An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.

Product: NSW2010-10T-POE-S-IN

For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.

Or ask on WhatsApp

Zhengzhou Huamai Information Technology Co., Ltd. · Tel / WhatsApp +86 186 1168 3168 · info@atlascommtech.com