
ZJIES3000D-16GT4GB
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIES3000D-16GT4GB is a managed DIN-rail industrial Ethernet switch with 16 × 10/100/1000Base-T ports and 4 × 1000Base-X SFP fiber slots. It offers full management — QoS, VLAN, IGMP Snooping/GMRP, Port Trunking, SNMP v1/v2/v3 — and multiple ring-redundancy protocols (STP/RSTP/MSTP/ERPS/ZJRing) for high reliability and interoperability. Its wide-temperature, EMC-hardened design meets demanding industrial field conditions, ideal for building fully-gigabit access-aggregation networks with fiber uplinks.
Is This the Right Fit?
Six real deployment scenarios matched to this model's actual datasheet specifications.
- Layer-2 managed switch only — no Layer-3 routing or inter-VLAN routing; pair with a Layer-3 core switch if cross-subnet routing is required.
- No PoE output on any port — powered end devices (cameras, APs) need a separate PoE injector or PoE switch.
- IP40 enclosure only — not sealed against dust/washdown; mount inside a cabinet or enclosure for direct outdoor exposure.
Key Features
- 16 × 10/100/1000Base-T + 4 × 1000Base-X SFP fiber slots
- Selectable DC 24V / 48V or AC 220V power input
- Redundancy: STP / RSTP / MSTP / ERPS / ZJRing
- Management: QoS, VLAN, IGMP Snooping / GMRP
- DIN-rail or wall mounting
- Wide operating temperature -40 ~ +75°C
- IP40 ingress protection
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100Base-T(X) & 100Base-FX Fast Ethernet |
| IEEE802.3ab | 1000Base-T(X) Ethernet |
| IEEE802.3z | 1000Base-X Ethernet |
| IEEE802.3x | Flow Control |
| IEEE802.3d | Spanning Tree Protocol |
| IEEE802.1w | Rapid Spanning Tree Protocol |
| IEEE802.1s | Multiple Spanning Tree Protocol |
| ITU-T G.8032 | Ethernet Ring Protection Switching (ERPS) |
| IEEE802.1p | Class of Service |
| IEEE802.1Q | VLAN Tag |
| IEEE802.3ad | LACP (Link Aggregation) |
| IEEE802.1x | User Authentication |
| IEEE802.1ab | LLDP |
Switching
| MAC Address Table | 8K |
| Packet Buffer | 4 Mbit |
| Forwarding | Store-and-forward |
Interfaces
| RJ45 Ports | 16 × 10/100/1000Base-T |
| SFP Fiber | 4 × 1000Base-X SFP slots |
| LED Indicators | Power, Link, Fiber, Status |
| Console | RS-232, RJ45, 9600bps, 8/N/1 |
Power
| DC 24V Input | 4-pin terminal, dual redundant; 12–36 VDC |
| DC 48V Input | 4-pin terminal, dual redundant; 36–56 VDC |
| AC 220V Input | 4-pin terminal, single input; 100–240 VAC |
| Power Consumption | Max 15 W |
| Power Protection | Reverse-polarity & overload |
| Alarm | 2-pin relay terminal |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2/3/4/5/6/8 Level 3 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Software Features
| MIB | RFC1215, RFC1213 MIB-II, RFC1157 SNMP-MIB, RFC1493 Bridge-MIB, RFC2674 VLAN-MIB, RFC1643, RFC1757, RSTP-MIB, Private MIB, LLDP-MIB |
| Management | SNMP v1/v2/v3; Web, Telnet, serial CLI; DHCP client; login password |
| Security | ACL L2–L4 filtering; port MAC filtering; MAC binding; 802.1X; RADIUS; DDoS self-defense |
| VLAN | Port & 802.1Q VLAN; up to 4094 VLANs (VID 1–4094); management VLAN |
| Link Aggregation | Static LACP; 2 groups × up to 4 ports |
| Ring Redundancy | STP/RSTP/MSTP; ERPS (G.8032); ZJRing self-healing ring <10ms |
| QoS | 4 priority classes (absolute / relative scheduling), mapped by 802.1p/DSCP into 8 hardware queues per port |
| Port Mirroring | One-way & two-way port mirroring |
| IGMP Multicast | IGMP Snooping v1/v2; up to 256 groups |
| Rate Limiting | Ingress/egress limiting, min 64 Kbps |
| Storm Suppression | Broadcast, multicast & unknown-unicast |
| Maintenance | Syslog, RMON, Ping, LLDP |
| SNTP | SNTP supported |
| Firmware | Web & serial TFTP upgrade |
| Config File | Import / export supported |
Physical
| Housing | IP40 metal enclosure |
| Mounting | DIN-rail (default), wall-mount optional |
| Dimensions | 65 (W) × 175 (H) × 150 (D) mm |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIES3000D-16GT4GB-AC | Industrial managed DIN-rail Layer-2 Ethernet switch — 16 × 10/100/1000Base-T, 4 × 1000Base-X SFP fiber slots, AC 220V (100–240 VAC) power. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional. | |
| ZJIES3000D-16GT4GB-DCL | Industrial managed DIN-rail Layer-2 Ethernet switch — 16 × 10/100/1000Base-T, 4 × 1000Base-X SFP fiber slots, DC 24V (12–36 VDC) with redundant power input. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional. | |
| ZJIES3000D-16GT4GB-DCH | Industrial managed DIN-rail Layer-2 Ethernet switch — 16 × 10/100/1000Base-T, 4 × 1000Base-X SFP fiber slots, DC 48V (36–56 VDC) with redundant power input. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional. |
Standard package does not include SFP optical modules.
Dimensions

Who uses it, where it goes and how to install it
Written for the ZJIES3000D-16GT4GB from the manufacturer's datasheet: managed Layer 2, 16 × 10/100/1000Base-T + 4 × 1000Base-X SFP slots (multimode 2 km / single-mode 10 km modules), STP/RSTP/MSTP, ERPS (G.8032) and ZJRing (<10 ms), AC 220V or redundant DC 24V/48V, max. 15 W.
Who it is for
- Aggregation cabinets in CCTV and ITS networks — 16 Gigabit copper ports collect the local cameras, and the 4 SFP slots carry the ring plus fiber spurs to nearby poles of up to 2 km (multimode) or 10 km (single-mode).
- Factory and process networks — QoS with 8 hardware queues per port, VLANs and storm suppression keep PLC and SCADA traffic stable when cameras share the same switch.
- Tunnels, substations and DC-powered rooms — -DCL (12–36V DC) and -DCH (36–56V DC) take two redundant feeds, EMS immunity is Level 3, and the 2-pin alarm terminal can signal a fault to the SCADA system.
- Integrators building mid-size rings — One model can be the ring node, the spur feeder and the uplink to the core, with config import/export to copy a tested setup to every cabinet; OEM and protocol-level customization are offered on the page.
Where and how to install
- Cabinet layout — The body is 65 × 175 × 150 mm (W × H × D), DIN rail by default or wall mount as an option. Put a fiber splice tray or patch panel next to it, a cable duct for 16 patch leads below, and keep it inside a closed cabinet because the housing is IP40.
- Power and alarm — Max. 15 W, about 0.63 A at 24 V or 0.31 A at 48 V. On -DCL/-DCH feed both inputs of the 4-pin terminal from separate supplies or breakers; -AC takes 100–240V AC on one input. Wire the 2-pin alarm terminal to a PLC or RTU input.
- Label and plan the 4 SFP slots — Decide before installation which slots are ring ports and which are spurs or uplinks, label both the slots and the fiber jumpers, and use the same slot numbers on every node so the configuration file can be reused. Modules are not included; keep dust caps on unused slots.
- Configure first, then close the ring — Set IP, VLANs and the ring through the Web page or RS-232 console (RJ45, 9600 bps, 8/N/1) before the last ring fiber is connected; a closed but unconfigured ring is a loop. Enable SNTP so Syslog entries carry the correct time for fault analysis.
- Earthing, surge and climate — Bond the cabinet and rail to earth and add Ethernet surge protectors on copper runs leaving the cabinet; fiber spurs need none and also isolate distant poles electrically. Use the wide-temperature grade (-40 to +75°C) in unheated cabinets and keep humidity non-condensing (5–95%).
Ports & ring planning
A typical node uses 2 SFP slots for the ring and 2 for fiber spurs to remote poles or for an aggregated uplink, with 16 copper ports for local devices. At an assumed 8 Mbps per camera, 16 local cameras add 128 Mbps; a 1000 Mbps ring link carries about 60 such cameras at half load (480 Mbps), leaving headroom when traffic reroutes after a fiber cut.
| ZJIES3000D-16GT4GB | |
|---|---|
| Copper ports | 16 × 10/100/1000Base-T |
| Fiber slots | 4 × 1000Base-X SFP (modules not included) |
| Typical slot use | 2 ring + 2 spur / uplink |
| Fiber reach (module chosen per order) | MM dual-fiber 2 km / SM dual-fiber 10 km |
| Ring protocols / recovery | STP/RSTP/MSTP, ERPS (G.8032), ZJRing <10 ms |
| QoS | 4 priority classes, 8 queues per port, 802.1p/DSCP |
| Link aggregation / VLAN / IGMP | 2 groups × 4 ports / 4094 / 256 groups |
| Power input | AC 100–240V / DC 12–36V ×2 / DC 36–56V ×2 |
| Max. power / DC current | 15 W / ≈0.63 A @ 24 V, ≈0.31 A @ 48 V |
| Operating temp. (wide / standard) | -40~75°C / -10~60°C |
| Size (W × H × D) / housing | 65 × 175 × 150 mm / IP40 |
- Pick multimode modules for spurs up to 2 km inside a site, single-mode for roadside or inter-site links up to 10 km.
- Pick the ZJIES3000D-16GT2GB if the node only needs the 2 ring fibers, or the ZJIES3000D-24GT4GB if 16 copper ports are not enough.
Values are from the manufacturer datasheet. Recovery time is given for ZJRing only. Slot use, 8 Mbps per camera and DC current (15 W ÷ voltage) are planning assumptions and arithmetic.
16-Port Gigabit Industrial Switch FAQ — ZJIES3000D-16GT4GB
What ports and uplinks does the ZJIES3000D-16GT4GB offer?
Why would I need 4 SFP fiber slots on an access switch?
Which redundancy protocols keep the network alive?
How do I access and configure the switch?
What are the power requirements and temperature range?
Can one ZJIES3000D-16GT4GB connect to two separate fiber rings?
How do I give PLC traffic priority over video on the ZJIES3000D-16GT4GB?
Which SFP modules do I need for the ZJIES3000D-16GT4GB?
If a ZJIES3000D-16GT4GB fails in the field, how do I replace it quickly?
Should I choose the ZJIES3000D-16GT4GB or the ZJIES3000D-24GT4GB?
What power connector does the ZJIES3000D-16GT4GB have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIES3000D-16GT4GB
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.



