ZTE Wantong S7850 · Core Switches
CLOS non-blocking modular core for campus and metro networks — four chassis from the 4U S7850-3 (3 service slots) to the 20U S7850-12 (12 service slots), with interface boards from gigabit copper to 6×100GE, M+N power redundancy and VSE 2.0 clustering. We engineer the slot-by-slot configuration around your port plan and deliver it with the rest of the network.
Lead time · In stock: at your forwarder’s China warehouse 3 days after payment · Not in stock: 7–15 working days · Then air 5–10 days / sea 25–45 days to your port
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →The ZTE Wantong S7850 series is the chassis core of the ZTE Wantong campus family, built for the core and aggregation layers of government, finance, utility, transport, campus, hospital and commercial park networks, as well as campus data centers and new-generation metro networks. The architecture is CLOS non-blocking with cell switching for load balancing, on fully programmable NP chips. All models separate main control from switching fabric, share the same interface boards (48×GE copper/fiber and PoE boards, 8/16/24/48-port 10GE boards, 6-port 40GE and 6-port 100GE/40GE boards), and take M+N power redundancy up to 3+3. VSE 2.0 clustering stacks chassis up to 80 km apart with 1.6 Tbps of stacking bandwidth and zero-perception switchover. This page lists the current four-chassis lineup — S7850-3, S7850-4, S7850-8 and S7850-12 — with figures quoted from the manufacturer's February 2026 datasheet only.
Four chassis, one board portfolio
Interface boards are interchangeable across all four — grow the chassis, keep the boards.
Is a chassis core what you actually need?
Plain-language guide — based only on what this series actually does.
- A 1U aggregation box with 10G uplinks — the ZTE Wantong S5860-E series is the lighter, cheaper answer
- Access-layer ports for desks, cameras and APs — that's the ZTE Wantong S5150 series
- Substation or roadside cabinets — our IEC 61850-3 industrial rack switches are built for those racks
Worried about the source? Order under your own company name.
Using your own freight forwarder? No problem.
Key Features
The series capability list — from the manufacturer's datasheet.
Who uses it, where it goes and how to plan the network core
Written for the ZTE Wantong S7850 modular core series from its own specifications: 4 CLOS chassis from 4U to 20U with 3 to 12 service slots, boards from 48×GE to 6×100GE, redundant MCUs and up to 3+3 power, VSE 2.0 clustering up to 80 km.
Who it is for
- Enterprise, finance and hospital IT — The core of a network that must stay up through a single failure: two MCUs, separate fabric boards (S7850-4/8/12), hot-swap PSUs and fans, plus NSF/GR so routing keeps forwarding while a main control unit switches over.
- Government, campus and transport projects — Core for parks, universities and transport hubs that collect many aggregation switches such as the S5860-E over 10G or 40G; VSE 2.0 can join two chassis in two machine rooms up to 80 km apart into one logical core.
- ISPs and metro network operators — MPLS L3VPN, VPLS, VPWS and H-VPLS, BGP with 6PE for IPv6, 802.1ag/802.3ah/Y.1731 OAM, and −48 V DC or 240/380 V HVDC inputs for telecom rooms.
- City-scale CCTV backbone integrators — Terminate hundreds of 10G links from district aggregation switches (a 48-port 10GE board per slot), connect storage and video platforms at 40G or 100G, and route multicast video with PIM-SM/SSM and IGMP instead of flooding it.
Where and how to install
- Machine room and rack space — Install in the main machine room in a 19-inch rack: 4U (S7850-3), 11U, 16U or 20U (S7850-12), all about 504 mm deep before boards, cables and optics. Leave room in front for fibre bending and patch panels, mount the chassis low in the rack, and use support rails or a tray rather than the front ears alone.
- A and B power feeds — Split the PSUs of the 1+1, 2+2 or 3+3 set across two independent feeds (A and B), each on its own UPS or DC plant, so losing one feed leaves a full set running. Inputs are −48/−60 V DC (−38 to −72 V), 110/220 V AC (90–290 V) or 240/380 V HVDC (192–400 V).
- Cooling — Long-term operating range is 0°C to +45°C (short-term -5°C to +50°C), so the core belongs in an air-conditioned room, not a closet. The chassis uses a direct airflow duct with 1 to 5 fan modules depending on size; keep its intake and exhaust sides open and match them to the room's cold and hot aisles, and fill unused slots with blank panels so air goes through the boards.
- Fibre and board layout — Spread each aggregation switch's two uplinks, and every LACP or MC-LAG bundle, across two different service boards, so one board failure or replacement does not cut a building off. Label every fibre at both ends, use patch panels instead of running trunk fibre straight to the boards, and check the optical-module diagnostics after commissioning.
- Management network — Connect the out-of-band management port to a separate management network, keep the RS232 (RJ45) console on a console server for remote recovery, and use SSH, SNMP, NETCONF/YANG and Telemetry rather than Telnet. Send Syslog, sFlow or IPFIX to your monitoring platform.
S7850 series planning: which of the 4 chassis
All four chassis use the same interface boards, so the choice is about service slots, redundancy and rack space. The port rows show the ceiling if every service slot held the same board type; real designs mix boards (for example 10GE for aggregation links plus 40GE/100GE for storage or a data center), so count slots per board type.
| S7850-3 | S7850-4 | S7850-8 | S7850-12 | |
|---|---|---|---|---|
| Chassis height | 4U | 11U | 16U | 20U |
| Total slots (MCU + fabric + service) | 5 (2 + 0 + 3) | 8 (2 + 2 + 4) | 14 (2 + 4 + 8) | 18 (2 + 4 + 12) |
| Switching capacity | 168 Tbps | 387 / 1161 Tbps | 645 / 1935 Tbps | 1290 / 3870 Tbps |
| Packet forwarding rate | 36800 Mpps | 115200 Mpps | 230400 Mpps | 460800 Mpps |
| Max 10GE ports (48-port 10GE board in every slot) | 144 | 192 | 384 | 576 |
| Max 100GE/40GE ports (6-port board in every slot) | 18 | 24 | 48 | 72 |
| Max GE / PoE ports (48-port board in every slot) | 144 | 192 | 384 | 576 |
| 25G ports | — | — | — | — |
| Power redundancy / fan modules | 1+1 / 1 | 2+2 / 2 | 3+3 / 4 | 3+3 / 5 |
| Typical position | compact core | mid-size core | campus core | metro / campus DC core |
- Pick the S7850-3 for a park core of up to a few dozen aggregation switches: 3 service slots, for example two 24-port 10GE boards for aggregation links and one 6-port 100GE/40GE board, in only 4U.
- Pick the S7850-4 or S7850-8 when the core needs separate fabric boards and 2+2 or 3+3 power; the S7850-8 doubles the service slots to 8 for full campus cores.
- Pick the S7850-12 for metro or campus data center cores: 12 service slots, up to 72 ports of 100GE/40GE, and two of them fit in 40U of a standard 42U rack.
— = not listed on the page. Maximum port counts are arithmetic (service slots × ports per board) and assume every service slot carries that board; MCU and fabric slots do not take interface boards. Boards, PSUs and optics are configured per project.
Full Specifications — Model by Model
Series specifications with one column per model — technical values in English. The highlighted column follows your model selection above.
Chassis Comparison
| Item | S7850-3 | S7850-4 | S7850-8 | S7850-12 |
|---|---|---|---|---|
| Switching capacity | 168 Tbps | 387 / 1161 Tbps | 645 / 1935 Tbps | 1290 / 3870 Tbps |
| Packet forwarding rate | 36800 Mpps | 115200 Mpps | 230400 Mpps | 460800 Mpps |
| Chassis height | 4U | 11U | 16U | 20U |
| Chassis dimensions (W×D×H, mm, excl. mounting ears) | 444×502.5×175 | 442×504×465 | 442×504×709 | 442×504×886.2 |
| Total slots | 5 | 8 | 14 | 18 |
| Main control (MCU) slots | 2 | |||
| Switching fabric slots | / | 2 | 4 | 4 |
| Service slots | 3 | 4 | 8 | 12 |
| Fan modules | 1 | 2 | 4 | 5 |
| Power redundancy | 1+1 | 2+2 | 3+3 | 3+3 |
Power Options — All Chassis
| Item | S7850-3 | S7850-4 | S7850-8 | S7850-12 |
|---|---|---|---|---|
| DC power | Rated −48 V DC / −60 V DC; max range −38 V DC to −72 V DC | |||
| AC power | Rated 110 V AC / 220 V AC, 50/60 Hz; max range 90–290 V AC, 45–66 Hz (at 90–175 V AC input, output derates to 45% of full load) | |||
| High-voltage DC | Rated 240 V DC / 380 V DC; max range 192–400 V DC | |||
Boards & Software — All Chassis
| Item | S7850-3 | S7850-4 | S7850-8 | S7850-12 |
|---|---|---|---|---|
| Interface board types | 48-port GE PoE copper / 24-port GE copper / 48-port GE fiber / 48-port GE copper / 6-port 100GE/40GE fiber / 24-port GE fiber / 48-port 10GE fiber / 6-port 40GE fiber / 16-port 10GE fiber / 8-port 10GE fiber / 24-port 10GE fiber | |||
| L2 features | VLAN, flexible QinQ, VLAN translation, STP/RSTP/MSTP | |||
| L3 features | VRRP, SuperVLAN, DHCP Server/Relay/Snooping, static routing, RIP, OSPF, IS-IS, BGP, policy routing, MCE | |||
| MPLS / MPLS VPN | LDP, VPLS, VPWS, H-VPLS, MPLS L3VPN, multicast VPN | |||
| Multicast | IGMP Snooping/Proxy, IGMP, PIM-DM/SM, PIM-SSM, MSDP | |||
| QoS | 802.1p, IP DSCP and MPLS EXP marking, rewriting and mapping / 8 hardware queues per port / SP, WRR, SP+WRR scheduling / port- and flow-based bandwidth management / tail drop and WRED congestion avoidance | |||
| Security | CPU anti-attack and overload protection, broadcast/multicast/unknown-unicast suppression, STP Root Guard, BPDU guard, uRPF, RIP/OSPF/BGP MD5 authentication, IP Source Guard, DAI, 802.1x / Portal / MAC authentication | |||
| IPv6 | IPv6, ND, DHCPv6, PMTU, MLD Snooping / static routing, RIPng, BGP4+, OSPFv3, IS-ISv6 / manual tunnels, 6to4, 6PE, ISATAP / IPv6 ACL / IPv6-based device management | |||
| Reliability | Redundant MCU, power and fan boards / LACP, MC-LAG, ERPS, VRRP, FRR, NSF, GR, VSE stacking, BFD | |||
| Data center features | VxLAN, BGP-EVPN, VxLAN OAM, VxLAN ping, VxLAN tracert | |||
| SDN | NETCONF and YANG models; automated deployment and policy follow-on | |||
| Device management | RS232 console (RJ45), out-of-band management port, CLI, Telnet, SSH, local & remote (RADIUS/TACACS+) AAA, SNMP, MIB, RMON, Syslog, fast batch inspection tools | |||
| O&M | 802.1ag, 802.3ah, Y.1731, zero-touch deployment, vertical virtualization, sFlow, Telemetry | |||
| Operating environment | Long-term 0°C to +45°C, short-term -5°C to +50°C, humidity 5%–95% | |||
| MTBF / MTTR | > 250000 h / < 30 min | |||
Modular Core Switch FAQ — S7850 Series
What chassis sizes does the S7850 series offer?
Which interface boards can I populate the slots with?
What power inputs and redundancy does it support?
Is it ready for data-center fabrics?
How reliable is it as a network core?
How do I get a configured quote for my project?
Which S7850 chassis do I need for 30 S5860-E aggregation switches?
Should two S7850 chassis run as one VSE 2.0 cluster or as an MC-LAG pair?
Can I run the S7850 on 110–127 V AC mains?
Will the S7850 interoperate with a Huawei, H3C or Cisco core or aggregation layer?
Which optical modules do the S7850 boards take, and are third-party optics supported?
When is an S7850 worth it instead of using a pair of S5860-E switches as the core?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Related Products



Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.