Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Not sure about the PoE budget? Size it with the calculator →
Need the PDF datasheet? Get it on WhatsApp →Overview
The Uniarch SW-2218-LP is a 19-inch rack-mount unmanaged PoE switch with 18 ports — 16 × 100Mbps PoE ports (IEEE 802.3af/at, up to 30 W each, 150 W total) plus 1 × 1000Mbps Gigabit uplink and 1 × 1000Mbps Combo uplink port. Three switchable working modes cover real sites: Normal, Secure (downlink ports isolated, talking only to uplinks) and Surveillance, which extends PoE transmission up to 250 m for far cameras. A fanless all-metal 1U housing and NDAA compliance make it a quiet, dependable power-and-data hub for larger camera systems.
Key Features
- Multiple working modes to address your business needs: Normal, Secure and Surveillance
- Support port traffic control
- Secure mode: all downlink ports communicate only with uplink ports
- Up to 250 m transmission distance on Surveillance mode
- Support buffer optimization
- All metal housing, safe and reliable
Specifications
Ports & Switching
| Ports Type | 16 × 100Mbps PoE ports (RJ45) + 1 × 1000Mbps GigaEthernet port + 1 × 1000Mbps Combo port |
| Uplink | 1 × 1000Mbps RJ45 + 1 × 1000Mbps Combo |
| Switching Capacity | 7.2 Gbps |
| Forwarding Performance | 5.36 Mpps |
| MAC | 16K |
| Packet Buffer | 4 Mbit |
PoE
| PoE Standard | IEEE 802.3af, IEEE 802.3at |
| PoE Mode | Mode A (pins 1/2/3/6), Mode B (pins 4/5/7/8) |
| Max PoE Power (total) | 150 W |
| Max PoE Power (single port) | 30 W |
| Prior Ports | Ports 1–8 |
Working Modes
| Normal (default) | All ports can communicate with each other |
| Secure | All downlink ports communicate only with uplink ports |
| Surveillance (EXTEND) | Transmission distance up to 250 m |
LED Indicators
| POWER | Steady on: AC input normal · Off: no AC input |
| PoE | Off: no PoE power supply · Steady on: PoE power supply normal |
| PoE-MAX | Off: total PoE load < 80% of budget · Steady on: > 85% of budget |
| LINK/ACT | Off: no link · Steady on: linked · Flashing: transmitting data |
Power & Environment
| Power Supply | Built-in, AC 100–240 V, 50/60 Hz |
| Max Power | 165 W |
| Cooling Fans | 0 (fanless) |
| Operating Temperature | 0 °C to 45 °C (32 °F to 113 °F) |
| Operating Humidity | 10% to 90% (non-condensing) |
Physical
| Dimensions (W×D×H) | 440 × 189.8 × 44 mm |
| Weight | 1.99 kg |
| Housing | All-metal, 19-inch rack-mount 1U |
Standards & Compliance
| IEEE Standards | IEEE802.3, IEEE802.3u, IEEE802.3az, IEEE802.3x, IEEE802.3af, IEEE802.3at |
| NDAA Compliant | Support |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| SW-2218-LP | Unmanaged rack-mount PoE switch — 18 network ports (16 × 100Mbps PoE 802.3af/at, max 30 W each, 150 W total; 1 × 1000Mbps uplink + 1 × 1000Mbps Combo), built-in AC 100–240V power, fanless metal 1U, NDAA compliant. |
One standard model. Built-in AC power supply (100–240 V input, no external adapter).
Dimensions

Who uses it, where it goes and how to install it
Written for the Uniarch SW-2218-LP from its own datasheet: 16 × 100 Mbps PoE ports (IEEE 802.3af/at), one 1000 Mbps RJ45 uplink plus one 1000 Mbps Combo uplink, 150 W PoE budget with 30 W per port, up to 250 m in Surveillance mode, fanless 1U metal body with built-in AC power.
Who it is for
- Installers with 9–16 fixed cameras — 16 PoE ports match a 16-channel NVR, and 16 typical 4 MP IR cameras at about 6 W use only 96 W of the 150 W budget, leaving room for one or two mini PTZs.
- Shops, offices and small hotels with a network cabinet — The fanless 1U body (440 × 189.8 × 44 mm, 1.99 kg) is silent next to staff, and AC 100–240 V is built in, so there is no external power brick to hide in the cabinet.
- Sites with a few far cameras: gates, car parks, perimeter — Surveillance (EXTEND) mode stretches camera runs up to 250 m instead of the usual 100 m, so a gate camera 150 m from the cabinet needs no extra switch or power point on the way.
- Projects that keep cameras apart from users — In Secure mode the 16 downlink ports can only talk to the two uplinks, so cameras cannot reach each other and a laptop plugged into a spare PoE port cannot browse the cameras. It is also listed as NDAA compliant.
Where and how to install
- Rack or shelf, with free air — It is a 19-inch 1U unit with no fan, so it cools only through its metal case. Keep the vents clear and leave space between it and a hot NVR; the operating range is 0 °C to 45 °C and 10% to 90% humidity (non-condensing). In a closed cabinet in a hot room add a cabinet fan, and do not put it in an outdoor box that drops below 0 °C.
- Power and UPS — Plug AC 100–240 V, 50/60 Hz straight into the switch; maximum consumption is 165 W. Size the UPS for 165 W plus the NVR and router, otherwise every camera goes dark at the first power cut.
- NVR on an uplink port, always — Connect the NVR to the 1000 Mbps RJ45 uplink or the Combo port, never to ports 1–16. The uplinks are the only Gigabit ports, and in Secure mode a PoE port can only talk to the uplinks, so an NVR on port 5 would lose every camera.
- Cable lengths — Camera runs: 100 m in Normal or Secure mode, up to 250 m in Surveillance (EXTEND) mode, with solid-copper Cat5e/Cat6 (not CCA). Copper uplinks are 100 m maximum; for a longer link to the NVR room put a fibre SFP module in the Combo port. Outdoors, keep cable joints in a junction box.
- Grounding and surge — The datasheet lists no surge rating. Bond the rack and the switch chassis to the building earth, and add Ethernet surge protectors on runs that come from poles or rooftops. Between buildings, fibre on the Combo port avoids ground-potential problems on long copper.
- Use the priority ports — Ports 1–8 keep PoE power first when demand nears 150 W. With this budget that can really happen, so put entrances, cash desks and PTZs on ports 1–8, less important cameras on 9–16, and label the patch panel so the order is kept.
PoE budget: how many cameras it really powers
150 W across 16 ports is about 9.4 W per port on average: plenty for ordinary fixed cameras (16 × 6 W = 96 W), but not for a full bank of PTZs. The 30 W per-port figure says what one port can give; the 150 W total says how many heavy loads fit at the same time, and at a full 30 W that is only 5.
| SW-2218-LP | |
|---|---|
| PoE ports | 16 × 100 Mbps RJ45 (ports 1–16) |
| Uplink ports | 1 × 1000 Mbps RJ45 + 1 × 1000 Mbps Combo (RJ45/SFP) |
| Total PoE budget | 150 W |
| Max. per port | 30 W (IEEE 802.3af/at) |
| Average per port with all ports in use | 9.4 W (150 W ÷ 16) |
| 4 MP IR cameras at ~6 W each | 16 (96 W) – limited by ports |
| Mini PTZ at ~13 W each | 11 (143 W) – limited by budget |
| Devices at the full 30 W | 5 (150 W, no margin) |
| Mixed example | 14 × 6 W + 2 × 13 W = 110 W |
| PoE-MAX light | off < 120 W (80%) · on > 127.5 W (85%) |
| Priority ports | 1–8 |
| PoE pin mode | Mode A (1/2/3/6), Mode B (4/5/7/8) |
| Switching capacity | 7.2 Gbps (5.36 Mpps) |
| Camera cable distance | 100 m Normal/Secure · up to 250 m Surveillance (EXTEND) |
| Uplink distance | 100 m copper · fibre via SFP in Combo port |
| Operating temperature | 0 °C to 45 °C |
| Power input | AC 100–240 V built-in, max. 165 W |
| Mounting / cooling | 19-inch rack 1U, 440 × 189.8 × 44 mm, fanless |
- Pick the SW-2218-LP for 9–16 fixed cameras on a 16-channel NVR, with at most two or three mini PTZs: 14 × 6 W + 2 × 13 W = 110 W stays under the 80% mark of 120 W.
- If the 16 ports must feed several PTZs or high-draw cameras, choose a 16-port model with a larger budget, such as the Uniview NSW2020-16T1GT1GC-POE-IN, instead of running this switch near 150 W.
- For 17–24 cameras use the 24-port SW-2226-LP (250 W); for 8 cameras or fewer the desktop SW-2110-LP is enough.
Camera draws of ~6 W (4 MP IR bullet/dome), ~13 W (mini PTZ) and 25 W or more (larger PTZ, heaters) are typical assumptions; check the max. power on each camera's datasheet. Budget, per-port, PoE-MAX and distance figures are from the Uniarch datasheet.
16-Port PoE Switch FAQ — SW-2218-LP
How many cameras can the SW-2218-LP support?
What uplinks does it offer toward the NVR?
Can it feed cameras beyond the usual cable distance?
Can it be rack-mounted and how is it powered?
Which PoE standards and wiring modes does it support?
The SW-2218-LP gives 30 W per port but only 150 W in total. Can every port run a 30 W device?
What do I give up when I switch the SW-2218-LP to Surveillance (EXTEND) mode for 250 m?
Are 100 Mbps camera ports and one Gigabit uplink on the SW-2218-LP enough for 16 4K cameras?
Will the SW-2218-LP power Hikvision, Dahua or other non-Uniarch cameras and work with their NVRs?
Which SFP module do I need for the Combo port on the SW-2218-LP?
SW-2218-LP, SW-2226-LP or SW-2110-LP: which one should I buy?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: SW-2218-LP
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.