SW-2226-LP
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Not sure about the PoE budget? Size it with the calculator →
Need the PDF datasheet? Get it on WhatsApp →Overview
The Uniarch SW-2226-LP is a 1U rack-mount L2 PoE switch with 26 ports — 24 × 100Mbps PoE ports (IEEE 802.3af/at, up to 30 W each, 250 W total) plus 1 × 1000Mbps GigaEthernet port and 1 × 1000Mbps Combo (RJ45/SFP) port for uplink. Three switchable working modes cover real sites: Normal, Secure (downlink ports isolated, talking only to uplinks) and Surveillance, which extends PoE transmission up to 250 m for far cameras. A fanless all-metal 19-inch housing and NDAA compliance make it a straightforward power-and-data aggregation switch for larger camera systems.
Key Features
- Multiple working modes to address your business needs: Normal, Secure and Surveillance
- Support port traffic control
- Support for secure mode, all downlink ports can communicate only with uplink ports
- Up to 250 m transmission distance on surveillance mode
- Support buffer optimization
- All metal housing, safe and reliable
Specifications
Ports & Switching
| Ports Type | 24 × 100Mbps PoE ports (RJ45) + 1 × 1000Mbps GigaEthernet port + 1 × 1000Mbps Combo port (RJ45/SFP) |
| Switching Capacity | 8.8 Gbps |
| Forwarding Performance | 6.55 Mpps |
| MAC Address Table | 16K |
| Packet Buffer | 4 Mbit |
PoE
| PoE Standard | IEEE 802.3af, IEEE 802.3at |
| PoE Mode | Mode B (pins 4/5/7/8) |
| Max PoE Power (total) | 250 W |
| Max PoE Power (single port) | 30 W |
| Prior Ports | Ports 1–8 |
Working Modes
| Normal (default) | All ports can communicate with each other |
| Secure | All downlink ports communicate only with uplink ports |
| Surveillance (EXTEND) | Transmission distance up to 250 m |
LED Indicators
| POWER | Steady on: AC input normal · Off: no AC input |
| PoE | Off: no PoE power supply · Steady on: PoE power supply normal |
| PoE-MAX | Off: total PoE load < 80% of budget · Steady on: > 85% of budget |
| LINK/ACT | Off: no link · Steady on: linked · Flashing: transmitting data |
Power & Environment
| Power Supply | Built-in, AC 100–240 V, 50/60 Hz |
| Max Power | 270 W |
| Cooling Fans | 0 (fanless) |
| Operating Temperature | 0 °C to 45 °C (32 °F to 113 °F) |
| Operating Humidity | 10% to 90% (non-condensing) |
Physical
| Dimensions (W×D×H) | 440 × 189.8 × 44 mm |
| Weight | 2.15 kg |
| Housing | All-metal, 19-inch rack-mount 1U |
Standards & Compliance
| IEEE Standards | IEEE802.3, IEEE802.3u, IEEE802.3az, IEEE802.3x, IEEE802.3af, IEEE802.3at |
| Switching | L2 |
| NDAA Compliant | Support |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| SW-2226-LP | L2 rack-mount PoE switch — 26 ports (24 × 100Mbps PoE 802.3af/at, max 30 W each, 250 W total; 1 × 1000Mbps GigaEthernet + 1 × 1000Mbps Combo uplink), built-in AC 100–240V power supply, fanless all-metal 1U housing, NDAA compliant. |
One standard model. Built-in AC power supply with power cord included (100–240 V input).
Dimensions

Who uses it, where it goes and how to install it
Written for the Uniarch SW-2226-LP from its own datasheet: 24 × 100 Mbps PoE ports (IEEE 802.3af/at, Mode B), one 1000 Mbps RJ45 uplink plus one 1000 Mbps Combo uplink, 250 W PoE budget with 30 W per port, up to 250 m in Surveillance mode, fanless 1U metal body with built-in AC power.
Who it is for
- Integrators with 17–24 camera projects — 24 PoE ports match a 24- or 32-channel NVR from one switch, and 24 typical 4 MP IR cameras at about 6 W use only 144 W of the 250 W budget.
- Warehouses, schools and car parks with some PTZs — With 250 W there is room for a mix: 20 fixed cameras at 6 W plus 4 mini PTZs at 13 W is 172 W, still below the 200 W (80%) mark where the PoE-MAX light starts to matter.
- Sites with far cameras on the perimeter — Surveillance (EXTEND) mode takes camera runs up to 250 m instead of 100 m, so fence-line and gate cameras can come straight back to the main cabinet without an outdoor switch.
- Projects that keep cameras apart from users — In Secure mode the 24 downlink ports can only talk to the two uplinks, so one infected or tampered camera cannot reach the others. It is also listed as NDAA compliant.
Where and how to install
- Rack position and heat — A 19-inch 1U unit, 440 × 189.8 × 44 mm and 2.15 kg, with no fan: it cools only through its metal case. Keep the vents clear and do not sandwich it tightly between an NVR and a UPS; the operating range is 0 °C to 45 °C and 10% to 90% humidity (non-condensing). Near a full 250 W load a closed cabinet in a hot room needs a cabinet fan.
- Power and UPS — Plug AC 100–240 V, 50/60 Hz straight into the switch; maximum consumption is 270 W. That is more than many small UPS units deliver, so size the UPS for 270 W plus the NVR and router, and check the UPS's watt rating, not only its VA.
- NVR on an uplink port, always — Connect the NVR to the 1000 Mbps RJ45 uplink and keep the Combo port for fibre or a link to the core switch. Never put the NVR on ports 1–24: they are 100 Mbps, and in Secure mode they can only talk to the uplinks, so the NVR would lose every camera.
- Cable lengths and all 8 wires — Camera runs: 100 m in Normal or Secure mode, up to 250 m in Surveillance (EXTEND) mode, with solid-copper Cat5e/Cat6 (not CCA). PoE is Mode B only, on pins 4/5/7/8, so terminate all 8 wires: a 4-wire cable carries data but no power. Copper uplinks are 100 m maximum; use a fibre SFP module in the Combo port for longer links.
- Grounding and surge — The datasheet lists no surge rating. Bond the rack and the switch chassis to the building earth, add Ethernet surge protectors on runs from poles and rooftops, and use fibre on the Combo port between buildings. With 24 outdoor cables on one switch, a single lightning hit can otherwise reach many ports at once.
- Use the priority ports — Ports 1–8 keep PoE power first if demand nears 250 W. Put entrances, cash desks and PTZs on ports 1–8, ordinary cameras on 9–24, and label the patch panel so the order survives later changes.
PoE budget: how many cameras it really powers
250 W across 24 ports is about 10.4 W per port on average: enough for a full set of fixed cameras (24 × 6 W = 144 W) plus a handful of mini PTZs. The 30 W per-port limit only tells you what one port can give; at a full 30 W the total budget is used up by 8 devices.
| SW-2226-LP | |
|---|---|
| PoE ports | 24 × 100 Mbps RJ45 (ports 1–24) |
| Uplink ports | 1 × 1000 Mbps RJ45 + 1 × 1000 Mbps Combo (RJ45/SFP) |
| Total PoE budget | 250 W |
| Max. per port | 30 W (IEEE 802.3af/at) |
| Average per port with all ports in use | 10.4 W (250 W ÷ 24) |
| 4 MP IR cameras at ~6 W each | 24 (144 W) – limited by ports |
| Mini PTZ at ~13 W each | 19 (247 W) – limited by budget |
| Devices at the full 30 W | 8 (240 W) – limited by budget |
| Mixed example | 20 × 6 W + 4 × 13 W = 172 W |
| PoE-MAX light | off < 200 W (80%) · on > 212.5 W (85%) |
| Priority ports | 1–8 |
| PoE pin mode | Mode B only (4/5/7/8) |
| Switching capacity | 8.8 Gbps (6.55 Mpps) |
| Camera cable distance | 100 m Normal/Secure · up to 250 m Surveillance (EXTEND) |
| Uplink distance | 100 m copper · fibre via SFP in Combo port |
| Operating temperature | 0 °C to 45 °C |
| Power input | AC 100–240 V built-in, max. 270 W |
| Mounting / cooling | 19-inch rack 1U, 440 × 189.8 × 44 mm, fanless |
- Pick the SW-2226-LP for 17–24 cameras on one NVR, including up to about 4 mini PTZs: 20 × 6 W + 4 × 13 W = 172 W stays below the 200 W (80%) mark.
- For 16 cameras or fewer, the 16-port SW-2218-LP (150 W) costs less rack space per port used and is enough for fixed cameras.
- If more than 8 ports must run heavy 25–30 W PTZs, split them across two switches rather than relying on the priority ports to sort out an overloaded 250 W budget.
Camera draws of ~6 W (4 MP IR bullet/dome), ~13 W (mini PTZ) and 25–30 W (larger PTZ, heaters) are typical assumptions; check the max. power on each camera's datasheet. Budget, per-port, PoE-MAX and distance figures are from the Uniarch datasheet.
24-Port PoE Switch FAQ — SW-2226-LP
How many cameras can the SW-2226-LP power at full load?
Can I uplink to the NVR room over fiber?
How far can it push PoE to distant cameras?
What are the rack size and power requirements?
What switching level and compliance does the SW-2226-LP offer?
Cameras draw more at night with IR or warm light on. Is the SW-2226-LP budget still enough for 24 of them?
The SW-2226-LP lists only PoE Mode B. Will it power Hikvision, Dahua or other non-Uniarch cameras?
What do I give up when I put SW-2226-LP ports into Surveillance (EXTEND) mode for 250 m?
Is one Gigabit uplink on the SW-2226-LP enough for 24 cameras going to the NVR?
Which SFP module fits the Combo port of the SW-2226-LP?
What is the difference between the SW-2226-LP and the SW-2218-LP, SW-2110-LP and SW-2106-LP?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: SW-2226-LP
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.