
ZJIES1000D-16T2S-DC
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIES1000D-16T2S-DC is an industrial unmanaged Fast Ethernet DIN-rail switch with 16 × 10/100Base-T copper ports and 2 × 100Base-FX fixed fiber uplinks — a higher-density 100M access/aggregation switch. It is plug-and-play — no configuration required — with store-and-forward switching, an 8K MAC table, 4 Mbit buffer and a fanless metal enclosure (65×150×120 mm) on DIN-rail (wall-mount optional). Powered by DC 24V (12–36V) or 48V (36–56V) with redundant dual input with reverse-polarity and overload protection, it draws under 12 W, operates from -40 to +75°C and offers strong EMC immunity — ideal for dense industrial edge and aggregation cabinets where a simple, rugged, silent 100M switch is needed.
Key Features
- Unmanaged plug-and-play — zero configuration
- 16 × 10/100Base-T + 2 × 100Base-FX fixed fiber (SC/ST/FC/LC)
- High-density design · 8K MAC · 4 Mbit buffer · store-and-forward
- DC 24V (12–36V) / 48V (36–56V), redundant dual input
- DIN-rail mounting (default) · wall-mount optional · 65×150×120 mm metal
- Fanless IP40 · wide temp -40 ~ +75°C · strong EMC immunity
- Reverse-polarity & overload protection · 5-year warranty
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100Base-T(X) & 100Base-FX Fast Ethernet |
| IEEE802.3x | Flow Control |
Switching
| MAC Address Table | 8K |
| Packet Buffer | 4 Mbit |
| Forwarding | Store-and-forward |
Interfaces
| RJ45 Ports | 16 × 10/100Base-T |
| Fiber Ports | 2 × 100Base-FX fixed (SC/ST/FC/LC optional) |
| Optical Distance | Multimode 2 km; single-mode 20 / 40 / 60 / 120 km |
| LED Indicators | Power, Link, Fiber |
Power
| Terminal | 4-pin terminal, dual redundant input |
| DC 24V Input | DC 24V, range 12–36V DC |
| DC 48V Input | DC 48V, range 36–56V DC |
| Power Consumption | Max 12 W |
| Power Protection | Reverse-polarity & overload |
Physical
| Housing | IP40 fanless metal enclosure |
| Mounting | DIN-rail (default), wall-mount optional |
| Dimensions | 65 (W) × 150 (H) × 120 (D) mm |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2/3/4/5/6/8 Level 3 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIES1000D-16T2S-DCL | Unmanaged DIN-rail Fast Ethernet switch — 16 × 10/100Base-T + 2 × 100Base-FX fixed fiber (SC/ST/FC/LC), DC 24V (12–36V), redundant input. | |
| ZJIES1000D-16T2S-DCH | Unmanaged DIN-rail Fast Ethernet switch — 16 × 10/100Base-T + 2 × 100Base-FX fixed fiber (SC/ST/FC/LC), DC 48V (36–56V), redundant input. | |
| ZJIES1000D-16T2S-AC | Unmanaged DIN-rail Fast Ethernet switch — 16 × 10/100Base-T + 2 × 100Base-FX fixed fiber (SC/ST/FC/LC), AC 220V (100–240V). | |
| ZJIES1000D-14T4S-AC | Unmanaged DIN-rail Fast Ethernet switch — 14 × 10/100Base-T + 4 × 100Base-FX fixed fiber (SC/ST/FC/LC), AC 220V (100–240V). | |
| ZJIES1000D-14T4S-DCL | Unmanaged DIN-rail Fast Ethernet switch — 14 × 10/100Base-T + 4 × 100Base-FX fixed fiber (SC/ST/FC/LC), DC 24V (12–36V), redundant input. | |
| ZJIES1000D-14T4S-DCH | Unmanaged DIN-rail Fast Ethernet switch — 14 × 10/100Base-T + 4 × 100Base-FX fixed fiber (SC/ST/FC/LC), DC 48V (36–56V), redundant input. |
This page covers the DC variants: -DCL = DC 24V (12–36V), -DCH = DC 48V (36–56V), both with redundant input. Fixed-fiber (100Base-FX) models: multimode 2 km, single-mode 20/40/60/120 km; SC/ST/FC/LC connectors optional. An AC 220V variant is also available. The requested model is ZJIES1000D-16T2S-DC.
Dimensions

Who uses it, where it goes and how to install it
Written for the ZJIES1000D-16T2S-DC from its own datasheet: 16 × 10/100Base-T copper + 2 × 100Base-FX fixed fibre ports, unmanaged, DC 24 V (12–36 V) or 48 V (36–56 V) redundant input, max 12 W, IP40 DIN-rail housing.
Who it is for
- CCTV integrators on roads, perimeters and campuses — A pole or field cabinet collects up to 16 copper devices and sends them back over fibre: multimode up to 2 km, single-mode 20 / 40 / 60 / 120 km, far beyond the 100 m copper limit.
- Traffic, tunnel and pipeline projects — Two fibre ports let cabinets be chained in a line (fibre in, fibre out) along a road, tunnel or pipeline, with copper ports for cameras, signal controllers and RTUs at each stop.
- Substations, telecom and 48 V DC sites — The -DCH build runs on 36–56 V DC from the station battery, both versions have dual redundant inputs, and fibre isolates the link from ground-potential differences between buildings.
- Factories linking workshops — PLC, HMI and drive cabinets in distant halls are joined over fibre without configuration, with 8K MAC, 4 Mbit buffer and store-and-forward switching.
Where and how to install
- DIN rail in a sealed field cabinet — The housing is IP40, so on poles and roadsides it must sit inside a weatherproof cabinet. Mount it upright on the DIN rail (65 × 150 × 120 mm) with space above and below for the fanless case, and leave room in front for the fibre bend.
- Fibre handling — Terminate the trunk cable in a small splice box or patch panel and use short patch cords to the switch; do not bend cords tightly or pull them by the connector. Keep dust caps on unused ports and clean connector ends before plugging in, since dirty ends are the most common cause of a dead link.
- Order the right fibre version — The fibre ports are fixed, not SFP slots, so mode (multimode or single-mode), reach (2 km MM; 20 / 40 / 60 / 120 km SM) and connector (SC, ST, FC or LC) are chosen at order and cannot be swapped on site. Match them to the cable already installed and to the device at the far end.
- DC wiring and fusing — Wire two separate DC sources to the two inputs of the 4-pin terminal. At the maximum 12 W the draw is about 0.5 A at 24 V (-DCL) or 0.25 A at 48 V (-DCH); fuse each input and check polarity, although reverse-polarity protection is built in.
- Earth, surge and condensation — Bond the housing and DIN rail to the cabinet earth, and fit Ethernet surge protectors on copper runs that leave the cabinet; the fibre runs need none. Order the wide-temperature build (-40 to +75°C) for outdoor cabinets, and add a heater or breather where humidity could condense, as the rating is 5–95% non-condensing.
Ports & link planning table
The ZJIES1000D-16T2S-DC adds two 100 Mbps fibre ports to a 16-port copper switch. Everything that crosses a fibre link shares 100 Mbps, and because the switch is unmanaged the fibres can be used as a line or star, never as a closed ring.
| ZJIES1000D-16T2S-DC | |
|---|---|
| Copper ports | 16 × 10/100Base-T RJ45 |
| Fibre ports | 2 × 100Base-FX fixed (SC/ST/FC/LC) |
| Fibre reach | MM 2 km · SM 20 / 40 / 60 / 120 km |
| Cameras per fibre link at 4 Mbps each (assumed) | ≈15 total → 60 Mbps |
| Ring / STP / VLAN | Not supported (unmanaged) |
| PoE | No |
| MAC table / buffer | 8K / 4 Mbit |
| Power input | -DCL 24 V (12–36 V) · -DCH 48 V (36–56 V), dual redundant |
| Max power / current | 12 W · ≈0.5 A @ 24 V · ≈0.25 A @ 48 V |
| Operating temperature | -10 ~ +60°C std · -40 ~ +75°C wide |
| Housing / mounting | IP40 metal · DIN-rail (wall optional) · 65×150×120 mm |
- Pick multimode (2 km) inside one plant or campus, and single-mode 20 km or more between sites or along roads; check which fibre is already in the ground before ordering.
- Pick ZJIES1000D-14T4S when one cabinet must feed three or four fibre directions; pick the copper-only ZJIES1000D-16T-DCL when everything is within 100 m.
- Pick a managed ZJIES3000D model when the fibre must close into a self-healing ring.
Camera count assumes about 4 Mbps per camera main stream and keeps a 100 Mbps fibre at about 60% load; in a chain, add up the cameras of every cabinet behind that fibre. Current = 12 W ÷ supply voltage.
DIN-Rail Fiber Switch FAQ — ZJIES1000D-16T2S-DC
How far can the fiber uplinks of the ZJIES1000D-16T2S-DC go?
What is the full port layout?
Which DC voltages does it accept?
When should I pick this model over a copper-only DIN-rail switch?
What environments is it rated for?
Does it need commissioning or software?
Can I connect the two fibre ports of the ZJIES1000D-16T2S-DC into a redundant ring?
Do I need to buy SFP modules for the ZJIES1000D-16T2S-DC?
Can the ZJIES1000D-16T2S-DC link over fibre to another brand's switch or a Gigabit SFP port?
How many cameras can a chain of ZJIES1000D-16T2S-DC cabinets carry back over one fibre?
Should I choose the ZJIES1000D-16T2S-DC or the ZJIES1000D-14T4S?
What power connector does the ZJIES1000D-16T2S-DC have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIES1000D-16T2S-DC
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.



