ZJIES1000D-8T-DC
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIES1000D-8T-DC is an industrial unmanaged Fast Ethernet DIN-rail switch with 8 × 10/100Base-T copper ports. It is plug-and-play — no configuration required — with store-and-forward switching, a compact fanless metal enclosure (32×144×95 mm) and DIN-rail mounting (wall-mount optional). Powered by DC 24V (12–36V) or 48V (36–56V) with redundant dual input and reverse-polarity / overload protection, it draws under 6 W, operates from -40 to +75°C and offers strong EMC immunity — ideal for compact cabinets and industrial edge sites where a simple, rugged, silent 100M switch is needed.
Key Features
- Unmanaged plug-and-play — zero configuration
- 8 × 10/100Base-T Fast Ethernet copper
- DIN-rail mounting (default) · wall-mount optional · compact 32×144×95 mm
- DC 24V (12–36V) / 48V (36–56V), redundant dual input
- Fanless IP40 metal · silent · under 6 W consumption
- Wide temperature -40 ~ +75°C · strong EMC immunity
- Reverse-polarity & overload protection · 5-year warranty
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100Base-T(X) & 100Base-FX Fast Ethernet |
| IEEE802.3x | Flow Control |
Switching
| MAC Address Table | 4K |
| Packet Buffer | 1 Mbit |
| Forwarding | Store-and-forward |
Interfaces
| RJ45 Ports | 8 × 10/100Base-T |
| Fiber Ports | None (copper-only model) |
| LED Indicators | Power, Link |
Power
| Terminal | 4-pin terminal, dual redundant input |
| DC 24V Input | DC 24V, range 12–36V DC |
| DC 48V Input | DC 48V, range 36–56V DC |
| Power Consumption | Max 6 W |
| Power Protection | Reverse-polarity & overload |
Physical
| Housing | IP40 fanless metal enclosure |
| Mounting | DIN-rail (default), wall-mount optional |
| Dimensions | 32 (W) × 144 (H) × 95 (D) mm |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2/3/4/5/6/8 Level 3 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIES1000D-8T-DCL | Unmanaged DIN-rail Fast Ethernet switch — 8 × 10/100Base-T, DC 24V (12–36V), redundant input. | |
| ZJIES1000D-8T-DCH | Unmanaged DIN-rail Fast Ethernet switch — 8 × 10/100Base-T, DC 48V (36–56V), redundant input. | |
| ZJIES1000D-8T-AC | Unmanaged DIN-rail Fast Ethernet switch — 8 × 10/100Base-T, AC 220V (100–240V). | |
| ZJIES1000D-6T2S-AC | Unmanaged DIN-rail Fast Ethernet switch — 6 × 10/100Base-T + 2 × 100Base-FX fixed fiber (SC/ST/FC), AC 220V (100–240V). MM 2 km / SM 10 km, single/dual fiber optional. | |
| ZJIES1000D-6T2S-DCL | Unmanaged DIN-rail Fast Ethernet switch — 6 × 10/100Base-T + 2 × 100Base-FX fixed fiber (SC/ST/FC), DC 24V (12–36V), redundant input. | |
| ZJIES1000D-6T2S-DCH | Unmanaged DIN-rail Fast Ethernet switch — 6 × 10/100Base-T + 2 × 100Base-FX fixed fiber (SC/ST/FC), DC 48V (36–56V), redundant input. |
This page covers the DC variants: -DCL = DC 24V (12–36V), -DCH = DC 48V (36–56V), both with redundant input. Fixed-fiber (100Base-FX) models: multimode 2 km, single-mode 20/40/60/120 km; single/dual fiber and SC/ST/FC optional. An AC 220V variant is also available in this series. The requested model is ZJIES1000D-8T-DC.
Dimensions

Who uses it, where it goes and how to install it
Written for the ZJIES1000D-8T-DC from its own datasheet: 8 × 10/100Base-T copper, unmanaged, DC 24V (12–36V) or 48V (36–56V) redundant input, max 6 W, 32 mm wide, -40 to +75°C.
Who it is for
- Machine builders and PLC panels — A 32 mm wide switch that runs from the panel's own 24 V DC supply links PLCs, HMIs, drives and remote I/O, which rarely need more than 100 Mbps.
- Substations, telecom and utility rooms on 48 V — The -DCH version takes 36–56V DC on two redundant inputs with reverse-polarity and overload protection, so it runs straight from a 48 V battery-backed system.
- Small CCTV cabinets and solar or battery sites — At 6 W maximum it uses at most 144 Wh per day, and the -DCL accepts 12–36V DC, which fits 24 V battery banks used on poles and remote sites.
- Integrators who need a low-cost spare — Plug-and-play with no settings to restore: a technician swaps the unit on the DIN rail, moves the cables and the network is back.
Where and how to install
- DIN rail inside a closed panel — The fanless housing is IP40, so it needs a closed panel or sealed outdoor cabinet. Clip it on the DIN rail (default) or use the wall-mount option, away from contactors and VFD power cables, and keep Ethernet cables in a separate duct.
- Wire both DC inputs — The 4-pin terminal has two redundant inputs. Wire them from two supplies or two separate breakers, check polarity before switching on, and fuse each feed. At 6 W maximum the current is about 0.25 A at 24 V or 0.125 A at 48 V.
- Copper only, 100 m per run — There is no fiber port. Keep each Cat5e/Cat6 run under 100 m; for links between buildings or longer runs, use the ZJIES1000D-6T2S from the same series, which has 2 fixed 100Base-FX fiber ports, or a separate media converter.
- Earthing and surge — Surge immunity is EN61000-4-5 Level 3. Bond the DIN rail and cabinet to earth, and fit Ethernet surge protectors on cables that run outdoors to cameras or devices on other structures.
- Temperature version and condensation — State the temperature version when ordering: wide is -40 to +75°C, standard is -10 to +60°C. Humidity must be non-condensing (5–95%), so use a filtered vent or heater in outdoor cabinets and enter cables from the bottom.
DC version, power and port planning
The two DC versions are identical except for the input range. All 8 ports, including the one you use as the uplink, run at 100 Mbps, so everything behind one ZJIES1000D-8T-DC shares 100 Mbps toward the NVR or core: fine for PLCs or a few cameras, tight for many cameras or cascades.
| ZJIES1000D-8T-DCL | ZJIES1000D-8T-DCH | |
|---|---|---|
| Input range | DC 12–36V (24V nominal) | DC 36–56V (48V nominal) |
| Redundant inputs | 2 (4-pin terminal) | 2 (4-pin terminal) |
| Max. power / current | 6 W / 0.25 A at 24 V | 6 W / 0.125 A at 48 V |
| Energy per day (max.) | 144 Wh | 144 Wh |
| Ports | 8 × 10/100Base-T | 8 × 10/100Base-T |
| Typical use: devices + uplink | 7 + 1 (100 Mbps) | 7 + 1 (100 Mbps) |
| MAC table / buffer | 4K / 1 Mbit | 4K / 1 Mbit |
| Size (W × H × D) | 32 × 144 × 95 mm | 32 × 144 × 95 mm |
| Operating temperature (wide / standard) | -40~75°C / -10~60°C | -40~75°C / -10~60°C |
- Pick -DCL for 24 V control panels and 24 V battery systems; pick -DCH for 48 V telecom or substation DC.
- Pick the ZJIES1000D-8GT instead (same 32 × 144 × 95 mm size and 6 W maximum) when the uplink carries many cameras or cascaded switches and 100 Mbps is not enough.
Values from the manufacturer datasheet. Current = 6 W ÷ voltage; energy per day = 6 W × 24 h; 7 + 1 is a planning assumption.
Industrial DIN-Rail Switch FAQ — ZJIES1000D-8T-DC
What ports does the ZJIES1000D-8T-DC provide?
How is it powered?
Does this switch need any configuration?
What temperature range does it support?
How is it installed and how big is it?
Can I power the ZJIES1000D-8T-DCL from a 12 V supply or a solar battery?
How many IP cameras can I connect to a ZJIES1000D-8T-DC?
What is the difference between the ZJIES1000D-8T-DC and the ZJIES1000D-8GT?
I need to reach a building 500 m away. Which model in this series should I use instead of the ZJIES1000D-8T-DC?
Can I connect two ZJIES1000D-8T-DC switches with two cables for backup?
What power connector does the ZJIES1000D-8T-DC have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIES1000D-8T-DC
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.