EMS-200
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The EMS-200 is an industrial IoT gateway for environment monitoring that bridges RS-232/485 serial devices and the TCP/IP Ethernet network, providing 1 × RS-232 and 3 × RS-485 serial ports plus 8 × DI and 2 × DO (relay) I/O interfaces. Built around a high-performance 32-bit processor with an embedded system for stable, reliable, low-power operation, it supports standard Modbus TCP and Modbus RTU/ASCII protocols alongside SNMP MIB-II, Real COM/TTY drivers and Web-console configuration. It is widely used in power monitoring, equipment-room monitoring, PLC, smart meters, gas meters, biometric devices and card readers.
Is This the Right Fit?
Six real deployment scenarios matched to this model's actual datasheet specifications.
- IP40 metal enclosure only — direct outdoor rain or dust exposure needs a cabinet or additional protection.
- Single DC 36–56V power input only — no redundant dual-input option is listed for this series.
- Fixed I/O count of 1×RS-232 + 3×RS-485 serial ports and 8×DI + 2×DO relay outputs — not user-expandable, and the datasheet lists no analog I/O (AI/AO) channel count for this model.
Key Features
- Industrial IoT gateway bridging RS-232/485 serial devices to the TCP/IP Ethernet network
- High-performance 32-bit processor · highly integrated, low-power design for industrial environments
- Standard Modbus protocol support: Modbus TCP, Modbus RTU/ASCII
- Digital/analog input-output and relay-output business interfaces
- Local real-time clock plus Modbus alarm-log storage
- Windows Real COM driver and Unix/Linux TTY driver — complete serial data delivered to user applications
- Universal Socket modes (TCP Server/Client, UDP) — connect two peer serial devices over the network without adding a computer
- 10/100M auto-negotiating Ethernet interface, manual mode setting supported
- Built-in 15KV ESD protection on all signals
- SNMP MIB-II support with Web-console management — easy to operate and maintain
Specifications
LAN
| Ethernet | 10/100 Mbps, RJ45 |
| Protection | Built-in 1.5KV electromagnetic protection |
Serial Interfaces
| Quantity | 1 × RS-232, 3 × RS-485 |
| Port Type | DB-9, terminal block |
| RS-232 Signal | TXD, RXD, GND |
| RS-485 Signal | Data+, Data-, GND |
| Serial Protection | All signals with 15KV ESD protection |
| Parity | None, Even, Odd, Mark, Space |
| Data Bits | 5, 6, 7, 8, 9 |
| Stop Bits | 1, 1.5, 2 |
| Flow Control | Xon/Xoff |
| Speed | 110 ~ 460800 bps |
I/O Interfaces
| Quantity | 8 × DI, 2 × DO (relay) |
| Port Protection | All I/O ports with photoelectric/electromagnetic isolation protection |
Power Output
| DC Power Output | 12V/30W DC high-power output |
Software Features
| Protocol | Modbus, ICMP, IP, TCP, UDP, DHCP, Telnet, SNMP, HTTP |
| Tool | Windows 2000/XP management software supported |
| Driver Support | Windows 2000/XP Real COM driver, Unix/Linux TTY driver |
| Configuration | Web browser, Telnet, Console |
Power Input Requirement
| 24V Power Input | Input range 36–56V DC |
| Power Consumption | 230mA @ 12V |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Physical
| Housing | IP40 metal enclosure |
| Mounting | Standard rack-mount installation |
| Dimensions | 240 (W) × 44 (H) × 110 (D) mm |
Warranty
| MTBF | 320,000 hours |
| Warranty Period | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJEMS-200-DCH | 19-inch 1U rack-mount environment monitoring host — 1×RS-232, 3×RS-485, 8×DI, 2×DO; supports Modbus RTU, Modbus TCP, virtual serial port and TCP Socket working modes; SNMP supported; IP40; DC48V powered. |
This page covers the EMS-200 series full-I/O variant (1×RS-232, 3×RS-485, 8×DI, 2×DO relay outputs). The listed configuration model ZJEMS-200-DCH is a 19-inch 1U rack-mount build with SNMP support, IP40 protection and DC48V power. A reduced-I/O sibling model, EMS-200-150 (2×RS-485, 6×DI, no RS-232, no relay output), is also available in the series. The requested model is EMS-200.
Dimensions

Who uses it, where it goes and how to wire it
Written for the EMS-200 (order code ZJEMS-200-DCH) from its own specifications: 1 × RS-232 and 3 × RS-485 serial ports, 8 × DI and 2 × DO relay outputs, Modbus TCP/RTU/ASCII and SNMP MIB-II, 12V/30W DC output for sensors, DC48V input (36–56V DC).
Who it is for
- Telecom and base-station operators — Runs from the site's 48V DC plant (36–56V DC input), and its 8 DI inputs pick up door, water-leak and smoke contacts in unmanned shelters, with the optional -40 to +75°C build for unheated sites.
- Data-room and server-room teams — A 1U rack unit that polls Modbus RTU devices on 3 RS-485 ports and is managed over SNMP MIB-II and a web console, so room alarms show up next to the other network gear in the NMS.
- Power and utility monitoring integrators — Bridges serial smart meters, gas meters and PLCs to Modbus TCP, keeps an alarm log with a local real-time clock, and the 2 relay outputs can switch a local alarm or a control circuit.
- Owners of legacy serial equipment — Real COM / TTY drivers and TCP Server/Client/UDP socket modes put RS-232 or RS-485 card readers, biometric terminals and controllers on the IP network, at 110–460800 bps.
Where and how to install
- Rack or cabinet, not open air — The EMS-200 is an IP40 metal unit, 240 × 44 × 110 mm, for standard rack mounting. Fit it in the equipment rack or an outdoor cabinet, never exposed to rain or dust. The body is narrower than a full 19-inch rack, so confirm the rack ears with us or set it on a cabinet shelf.
- Power from the 48V DC system — Feed it from the site's 48V DC distribution through its own breaker or fuse; the input accepts 36–56V DC. Check polarity on the terminal before switching on, and keep it on the battery-backed DC bus so alarms still report during a mains failure.
- Wire DI sensors as contacts — Connect door contacts, water-leak, smoke and similar alarm sensors with switch outputs to the 8 DI inputs, one sensor per input, and label each one in the web console. Sensors that need power can take it from the 12V/30W DC output.
- RS-485 bus wiring — Use shielded twisted pair from the Data+, Data- and GND terminals, chained device to device rather than in a star, and give every Modbus RTU device on a port its own address and the same baud rate and parity. The 3 RS-485 ports let you keep, for example, meters, air conditioners and UPS on separate buses.
- Temperature and environment — The standard build works from -10 to +60°C at 5–95% humidity, non-condensing. For outdoor cabinets or unheated shelters that go below -10°C or above +60°C, order the wide-temperature build (-40 to +75°C) and say so in your inquiry.
Interfaces and limits at a glance
Use this to count your monitoring points before ordering: switch-type sensors go on the DI inputs, Modbus RTU sensors, meters and controllers on the serial ports, and local alarms or control on the relays. If 2 × RS-485 and 6 × DI are enough and you need no RS-232 or relay output, the smaller EMS-200-150 also exists in the series.
| EMS-200 (ZJEMS-200-DCH) | |
|---|---|
| Serial ports | 1 × RS-232 (DB-9) + 3 × RS-485 (terminal block) |
| Serial speed / protection | 110–460800 bps; 15KV ESD on all signals |
| Digital inputs (switch sensors) | 8 × DI, isolated |
| Relay outputs | 2 × DO (relay), isolated |
| Analog inputs (4–20 mA / 0–10 V) | Not listed |
| Power output for sensors | 12V / 30W DC (= 2.5 A total) |
| Ethernet | 1 × RJ45 10/100 Mbps (copper ≤ 100 m) |
| Protocols / management | Modbus TCP/RTU/ASCII, SNMP MIB-II, HTTP, Telnet, DHCP; Web / Telnet / Console |
| Power input | DC48V, range 36–56V DC |
| Operating temperature | -10 to +60°C (wide-temp build -40 to +75°C) |
| Housing / size | IP40 metal, 240 × 44 × 110 mm, rack mount |
- Count switch-type alarm points (doors, water leak, smoke): up to 8 fit on one EMS-200.
- For temperature and humidity, choose RS-485 Modbus RTU sensors, since no analog input is listed.
- Add up the draw of everything on the 12V output and keep it under 30 W; give sirens or strobes their own supply.
Values are from this page's specification table; 2.5 A = 30 W ÷ 12 V. The 100 m copper limit is the general Ethernet rule, not a page value.
Environment Monitoring Gateway FAQ — EMS-200
Which ports does the EMS-200 provide?
What protocols does the EMS-200 support?
What is the EMS-200 typically used for?
What power input does it need?
Can it handle tough electrical and temperature conditions?
Which sensors can I connect to the EMS-200, and can it read 4–20 mA temperature sensors?
How does the EMS-200 send an alarm: SMS, email or SNMP?
How many Modbus devices can I put on each RS-485 port of the EMS-200, and how far can the cable run?
Can the EMS-200's 12V output power my sensors?
What can the two relay outputs on the EMS-200 switch?
Should I choose the EMS-200 or the smaller EMS-200-150?
What power connector does the EMS-200 have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: EMS-200
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.