
ZJIES1000D-PN
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIES1000D-PN series is an industrial unmanaged DIN-rail ProfiNet industrial Ethernet switch with 8 × 10/100Base-T ports, compatible with EtherNet/IP, ProfiNet and Modbus TCP industrial Ethernet protocols for industrial automation control applications. It mounts on a DIN rail (wall-mount optional) and accepts DC 24V/48V or AC 220V power input across a wide voltage range, with overload and reverse-polarity protection plus strong EMC immunity to meet varied industrial requirements. This allocates network bandwidth efficiently, makes better use of network resources, and ensures fast, reliable data transmission in harsh industrial environments.
Is This the Right Fit?
Six real deployment scenarios matched to this model's actual datasheet specifications.
- Unmanaged fixed-configuration switch — no VLAN, RSTP, or ring-redundancy protocol support; the DIP switch only provides simple broadcast storm suppression on/off, not managed ring recovery.
- Fixed 8 × 10/100Base-T copper ports only — no gigabit or fiber uplink option on this series.
- IP40 enclosure only — not rated for direct outdoor rain/dust exposure; needs a cabinet or additional protection outdoors.
Key Features
- 8 × 10/100Base-T Fast Ethernet ports
- Compatible with EtherNet/IP, ProfiNet, Modbus TCP industrial Ethernet protocols
- DIP-switch broadcast storm suppression — on/off selectable
- DIP-switch QoS — on/off selectable
- DIP-switch event alarm — on/off selectable
- DC 24V/48V or AC 220V power input options
- Industrial IP40 protection · wide-temp -40 ~ +75°C operation
- DIN-rail or wall-mount installation
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100BaseT(X) and 100BaseFX Fast Ethernet |
| IEEE802.3x | Flow Control |
| IEEE 802.1P | Traffic priority, dynamic multicast filtering |
Switching
| Priority Queues | 8 |
| MAC Address Table | 16K |
| Packet Buffer | 4 Mbit |
| Forwarding Rate | 1.2 Mpps |
| Switching Latency | < 10 μs |
Interfaces
| RJ45 Ports | 8 × 10/100Base-T |
| LED Indicators | Power, Port |
DIP Switches
| Broadcast Storm Suppression | On/off via DIP switch |
| QoS | On/off via DIP switch |
| Event Alarm | On/off via DIP switch |
Power
| 24V Input | 4-pin terminal, dual redundant input; 24VDC supports 12–36VDC |
| 48V Input | 4-pin terminal, dual redundant input; 48VDC supports 36–56VDC |
| 220V Input | 4-pin terminal, single power input; 220V supports 100–240VAC |
| Power Consumption | Max 3 W |
| Power Protection | Reverse-polarity, overload & redundancy protection |
Physical
| Housing | IP40 metal enclosure |
| Mounting | DIN-rail (default), wall-mount optional |
| Dimensions | 55 (W) × 150 (H) × 120 (D) mm |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2/3/4/5/6/8 Level 3 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIES1000D-PN-8T-AC | Industrial unmanaged DIN-rail ProfiNet switch — 8 × 10/100Base-T, AC 220V (100–240VAC). Compatible with EtherNet/IP, ProfiNet, Modbus TCP industrial Ethernet protocols. | |
| ZJIES1000D-PN-8T-DCL | Industrial unmanaged DIN-rail switch — 8 × 10/100Base-T, DC 24V (12–36VDC), redundant power input. Compatible with EtherNet/IP, ProfiNet, Modbus TCP industrial Ethernet protocols. | |
| ZJIES1000D-PN-8T-DCH | Industrial unmanaged DIN-rail switch — 8 × 10/100Base-T, DC 48V (36–56VDC), redundant power input. Compatible with EtherNet/IP, ProfiNet, Modbus TCP industrial Ethernet protocols. |
This page covers the ZJIES1000D-PN series: all variants share 8 × 10/100Base-T ports and are compatible with EtherNet/IP, ProfiNet, and Modbus TCP industrial Ethernet protocols. Power options: -8T-AC = AC 220V (100–240VAC); -8T-DCL = DC 24V (12–36VDC), redundant dual input; -8T-DCH = DC 48V (36–56VDC), redundant dual input. The requested model is ZJIES1000D-PN.
Dimensions

Who uses it, where it goes and how to install it
Written for the ZJIES1000D-PN series from the manufacturer's datasheet: unmanaged, 8 × 10/100Base-T, compatible with EtherNet/IP, ProfiNet and Modbus TCP, DIP switches for broadcast-storm suppression, QoS and event alarm, 24 V DC / 48 V DC (redundant) or 220 V AC input, max. 3 W, -40 to +75 °C (wide-temperature version), IP40 DIN-rail housing.
Who it is for
- PLC panel builders and machine OEMs — Eight 100 Mbps ports join a PLC, remote I/O, drives and an HMI inside one panel, and the -8T-DCL version runs from the panel's own 24 V DC (12–36 V) with two redundant inputs.
- Automation lines on ProfiNet, EtherNet/IP or Modbus TCP — Wire-speed forwarding (1.2 Mpps), latency under 10 μs, 8 priority queues with IEEE 802.1p and a 16K MAC table keep cyclic controller traffic moving when the same network also carries HMI or camera data.
- Water, energy and process plants — The -8T-DCH version (36–56 V) runs from a 48 V battery plant, and the wide-temperature version (-40 to +75 °C) with EN61000-4 Level 3 immunity suits remote pumping stations and outdoor control cabinets.
- Maintenance teams who want no software — Storm suppression, QoS and the event alarm are set with DIP switches on the unit, so a replacement can be swapped by an electrician without a laptop or console cable.
- Integrators and distributors — Three power versions (-8T-AC, -8T-DCL, -8T-DCH) cover most panels, and neutral casing and OEM customisation are offered on the page.
Where and how to install
- DIN rail in the control panel — Clip it onto a 35 mm DIN rail (wall mounting optional); it is 55 mm wide. The IP40 housing keeps out dust and fingers but not water or wash-down, so it must be in a closed panel. At max. 3 W it runs cool, but keep it away from braking resistors and transformers.
- Choose and wire the power version — -8T-DCL takes 12–36 V DC and -8T-DCH 36–56 V DC, each with two redundant inputs on the 4-pin terminal: feed them from two separate supplies, each fused. -8T-AC takes 100–240 V AC on a single input; put it on a breaker and keep the mains wiring segregated from the Ethernet cables.
- Set the DIP switches before commissioning — Decide the broadcast-storm, QoS and event-alarm settings at installation and record them on the panel drawing, so a replacement unit is set the same way. Storm suppression limits the damage of an accidental loop but does not replace good topology: wire in a line or star.
- Cable routing near drives — Every port is copper, so each run is limited to 100 m. Use shielded industrial Ethernet cable near VFDs, keep it apart from motor cables and cross them at right angles, and earth cable shields and the DIN rail at the panel. Links leaving the building need surge protection or fibre.
- Temperature and condensation — The standard version is rated -10 to +60 °C; for outdoor or unheated cabinets order the wide-temperature version (-40 to +75 °C). Humidity is rated 5–95 % non-condensing, so add an anti-condensation heater or breather in humid plants and seal cable entries.
Ports and power planning
All three versions have the same eight 100 Mbps copper ports and switching performance; only the power input differs. 1.2 Mpps is about the full line rate of eight 100 Mbps ports with minimum-size frames, so the switch does not become the bottleneck for small, frequent control packets.
| ZJIES1000D-PN-8T-DCL | ZJIES1000D-PN-8T-DCH | ZJIES1000D-PN-8T-AC | |
|---|---|---|---|
| Copper ports | 8 × 10/100Base-T | 8 × 10/100Base-T | 8 × 10/100Base-T |
| Fibre ports / PoE | — / — | — / — | — / — |
| Power input | 24 V DC (12–36 V) | 48 V DC (36–56 V) | 220 V AC (100–240 V) |
| Redundant inputs | 2 | 2 | 1 (single) |
| Power consumption | Max. 3 W | Max. 3 W | Max. 3 W |
| Input current at 3 W | ≈0.25 A @ 12 V · ≈0.13 A @ 24 V | ≈0.06 A @ 48 V | — |
| Forwarding rate / latency | 1.2 Mpps / < 10 μs | 1.2 Mpps / < 10 μs | 1.2 Mpps / < 10 μs |
| MAC table / buffer / priority queues | 16K / 4 Mbit / 8 | 16K / 4 Mbit / 8 | 16K / 4 Mbit / 8 |
| DIP switches | Storm suppression · QoS · event alarm | Storm suppression · QoS · event alarm | Storm suppression · QoS · event alarm |
| Ring redundancy | — (unmanaged) | — (unmanaged) | — (unmanaged) |
| Max. copper run per port | 100 m | 100 m | 100 m |
| Operating temperature | -10 ~ +60 °C (std) · -40 ~ +75 °C (wide) | -10 ~ +60 °C (std) · -40 ~ +75 °C (wide) | -10 ~ +60 °C (std) · -40 ~ +75 °C (wide) |
| Housing / size | IP40 metal · 55 × 150 × 120 mm | IP40 metal · 55 × 150 × 120 mm | IP40 metal · 55 × 150 × 120 mm |
- Pick -8T-DCL for 24 V control panels, -8T-DCH for 48 V telecom or battery plants, -8T-AC where only mains is available (single input, no redundancy).
- If a device is more than 100 m away, add a fibre media converter such as the ZJIC200-2, or use a fibre model such as the ZJIES1000D-6T4F.
- For a redundant ring, VLANs or SNMP diagnostics, use a managed model such as the ZJIES3000D-8GT.
Values from the manufacturer's ZJIES1000D-PN datasheet. Currents are max. power ÷ voltage. Line rate check: 8 ports × about 148,800 minimum-size frames per second at 100 Mbps ≈ 1.19 Mpps.
ProfiNet Industrial Switch FAQ — ZJIES1000D-PN
Which industrial protocols does the ZJIES1000D-PN support?
How do I wire the power input?
Can it run in hot or freezing plant environments?
How is it installed and configured?
How reliable is it for long-term deployments?
Is the ZJIES1000D-PN a PROFINET-certified switch, and will it show up in the TIA Portal topology view?
Should I switch on the QoS DIP switch on the ZJIES1000D-PN?
With broadcast-storm suppression on, can I wire ZJIES1000D-PN switches in a ring?
What does the event alarm on the ZJIES1000D-PN report, and can I wire it to my PLC?
A drive on the line is 150 m from the panel. Can the ZJIES1000D-PN reach it?
What power connector does the ZJIES1000D-PN have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIES1000D-PN
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.



