EMS-200-150
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The EMS-200-150 is a compact industrial IoT gateway and environment monitoring host that connects RS-485 serial devices and digital-input sensors to a TCP/IP Ethernet network through 2 × RS-485 ports and 6 × DI channels. Compared with the full-featured EMS-200, this version omits the RS-232 port and DO relay outputs, keeping the same 32-bit processor, Modbus TCP/RTU/ASCII, SNMP MIB-II and Syslog support inside a smaller 180×44×96.5mm 1U rack-mount chassis. Powered by DC48V (36–56VDC input, 230mA@12V), its I/O is limited to 6 × DI digital inputs with no relay/DO output, making it suited to status-monitoring points rather than remote switching control.
Is This the Right Fit?
Six real deployment scenarios matched to this model's actual datasheet specifications.
- No RS-232 port — only 2 × RS-485 ports are available, so RS-232-only serial devices cannot be connected directly.
- No DO relay outputs — only 6 × DI digital inputs are provided, so remote switching/control of external circuits is not supported; monitoring only.
- IP40 enclosure only — needs a rack cabinet or additional protection for direct outdoor rain/dust exposure.
Key Features
- 32-bit high-performance processor for stable, reliable operation
- Modbus TCP and Modbus RTU/ASCII protocol support
- Local real-time clock with Modbus alarm-record storage
- Windows Real COM driver plus Unix/Linux TTY driver
- Generic Socket modes — TCP Server/Client and UDP
- Serial-tunneling mode links two peer serial devices over the network without adding a PC
- 10/100M auto-negotiating Ethernet port, manual setting supported
- All serial and I/O signals carry built-in 15KV ESD protection
- SNMP MIB-II support for standard network management
- Syslog standard logging protocol support
- Web / Telnet / Console management for easy configuration and maintenance
Specifications
LAN
| Ethernet | 10/100 Mbps, RJ45 |
| Protection | Built-in 1.5KV electromagnetic protection |
Serial Interfaces
| Quantity | 2 × RS-485 |
| Port Type | Terminal block |
| RS-485 Signal | Data+, Data- |
| Port Protection | All signals 15KV ESD protection |
| Parity | None, Even, Odd, Mark, Space |
| Data Bits | 5, 6, 7, 8, 9 |
| Stop Bits | 1, 1.5, 2 |
| Flow Control | Xon/Xoff |
| Speed | 110 ~ 460,800 bps |
I/O Interface
| Quantity | 6 × DI |
| Port Protection | All I/O ports photoelectric/electromagnetic isolation protection |
Power Output
| DC Power Output | 12V/30W high-power DC output |
Software Features
| Protocol | Modbus, ICMP, IP, TCP, UDP, DHCP, Telnet, SNMP, HTTP, Syslog |
| Tool | Windows 2000/XP management software supported |
| Driver Support | Windows 2000/XP Real COM driver, Unix/Linux TTY driver |
| Configuration | Web browser, Telnet, Console |
Input Power Requirement
| 48V Power Input | Input range 36–56V DC |
| Power Consumption | 230mA @ 12V |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Physical
| Housing | IP40 metal enclosure |
| Mounting | Standard rack-mount |
| Dimensions | 180 (W) × 44 (H) × 96.5 (D) mm |
Warranty & Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJEMS-200-150-DCH | 19-inch 1U rack-mount environment monitoring host — 2×RS-485, 6×DI, supports Modbus RTU, Modbus TCP, virtual serial port and TCP Socket modes; SNMP supported, IP40, DC48V powered. |
This page covers the model requested as EMS-200-150. The datasheet order code is ZJEMS-200-150-DCH (chassis silkscreen: ZJEMS-150), denoting the DC48V-powered 2×RS-485 + 6×DI environment monitoring host. No other port or power variant is listed in this datasheet.
Dimensions

Who uses it, where it goes and how to wire it
Written for the EMS-200-150 (order code ZJEMS-200-150-DCH) from its own specifications: 2 × RS-485 ports and 6 × DI inputs, no RS-232 and no relay output, Modbus TCP/RTU/ASCII, SNMP MIB-II and Syslog, 12V/30W DC output for sensors, DC48V input (36–56V DC), 180 × 44 × 96.5 mm.
Who it is for
- Telecom and base-station operators — Runs on the site's 48V DC (36–56V DC input) and reports door, water-leak and smoke contacts from unmanned shelters on its 6 DI inputs; the optional -40 to +75°C build suits unheated sites.
- Small server rooms and network cabinets — At 180 × 44 × 96.5 mm it fits shallow wall cabinets, and 2 RS-485 ports read Modbus RTU temperature/humidity sensors or a UPS while the DI inputs watch doors and leaks.
- IT and NOC teams with a syslog server — SNMP MIB-II and Syslog support let the unit sit in the same NMS and central log server as the switches and routers, with a web, Telnet or console interface for setup.
- Projects that only need status monitoring — With 6 DI and no relay output it reads open/closed and alarm states but switches nothing on site, a lower-cost fit where control is handled by other equipment.
Where and how to install
- Inside a rack or cabinet — The housing is an IP40 metal case, 180 × 44 × 96.5 mm, for rack mounting. Install it in the equipment rack or a closed outdoor cabinet, never exposed to rain or dust. It is much narrower than a 19-inch rack, so confirm the rack ears with us or fix it on a cabinet shelf.
- Power from the 48V DC bus — Feed it from the 48V DC distribution through its own breaker or fuse (input 36–56V DC) and check polarity before switching on. Keep it on the battery-backed side so the host still reports while mains is down, which is when door and temperature alarms matter most.
- DI wiring: one sensor per input — Connect switch-output sensors (door contact, water leak, smoke) to the 6 DI inputs and name each input in the web console. Sensors that need power can take it from the 12V/30W DC output; run sensor cable away from mains cables.
- Two RS-485 buses — Each RS-485 port has Data+ and Data- terminals. Use shielded twisted pair, chain the devices one after another, give each Modbus RTU device its own address and match baud rate and parity. A common split is sensors on one port and the UPS or air conditioner on the other.
- Temperature range — The standard build works from -10 to +60°C at 5–95% humidity, non-condensing. Shelters or outdoor cabinets that go colder or hotter need the wide-temperature build (-40 to +75°C), which must be requested when ordering.
Interfaces and limits at a glance
Count your monitoring points against this table before ordering. If you need an RS-232 device, a third RS-485 bus, more than 6 contact sensors or a relay to switch a siren, the larger EMS-200 is the model in the same series.
| EMS-200-150 (ZJEMS-200-150-DCH) | |
|---|---|
| Serial ports | 2 × RS-485 (terminal block, Data+/Data-); no RS-232 |
| Serial speed / protection | 110–460800 bps; 15KV ESD on all signals |
| Digital inputs (switch sensors) | 6 × DI, isolated |
| Relay outputs | None |
| Analog inputs (4–20 mA / 0–10 V) | Not listed |
| Power output for sensors | 12V / 30W DC (= 2.5 A total) |
| Ethernet | 1 × RJ45 10/100 Mbps (copper ≤ 100 m) |
| Protocols / management | Modbus TCP/RTU/ASCII, SNMP MIB-II, Syslog, HTTP, Telnet, DHCP; Web / Telnet / Console |
| Power input | DC48V, range 36–56V DC |
| Operating temperature | -10 to +60°C (wide-temp build -40 to +75°C) |
| Housing / size | IP40 metal, 180 × 44 × 96.5 mm, rack mount |
- Up to 6 contact sensors (doors, water leak, smoke) with one sensor per input, so each alarm shows which point tripped.
- For temperature and humidity, choose RS-485 Modbus RTU sensors, since no analog input is listed.
- Keep everything on the 12V output under 30 W in total.
Values are from this page's specification table; 2.5 A = 30 W ÷ 12 V. The 100 m copper limit is the general Ethernet rule, not a page value.
Industrial IoT Gateway FAQ — EMS-200-150
What devices can I connect to the EMS-200-150?
How is the EMS-200-150 different from the EMS-200?
How is it powered on site?
Is it protected enough for harsh equipment rooms?
How do I configure and integrate it with my software?
Can the EMS-200-150 read 4–20 mA or 0–10 V analog sensors?
How does the EMS-200-150 report an alarm: SMS, email, SNMP or Syslog?
I have more than 6 alarm contacts. Can several sensors share one DI input on the EMS-200-150?
How many Modbus RTU devices can each RS-485 port of the EMS-200-150 handle, and how long can the cable be?
Can the EMS-200-150's 12V output power my sensors?
What power connector does the EMS-200-150 have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: EMS-200-150
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.