Skip to main content
Home › Industrial Switches › ZJIES3000D-8GT

ZJIES3000D-8GT

Industrial · Managed L2
Managed DIN-Rail Industrial Ethernet Switch · 8×GE Copper
Project-Based Pricing
Volume & combo discounts — get your quote
In-stock models: 3 days to your forwarder's warehouse in China after payment · Out-of-stock: 7–15 working days · then air 5–10 days or sea 25–45 days to your port
✓ Project-level customization & OEM supported
Get Best Price on WhatsAppRequest a quote ↓

Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA

Need the PDF datasheet? Get it on WhatsApp →
How to get a better price
Volume DiscountOrder 50+ pcs of this model
CONTACT US
Project Combo DiscountMix any categories & models storewide in one order — no quantity limit
BIGGER
Verified Project DiscountDistributor, integrator or end user with a real project? Send the BOQ — project pricing plus free system design. Partner projects are protected: we never quote your end customer behind you
BIGGEST
All discounts are quoted personally — message me on WhatsApp ↑
◆-40 ~ 75°C
◆IP40 Fanless
◆ERPS Ring <50ms
◆4094 VLANs
◆5-Year Warranty

Overview

The ZJIES3000D-8GT is an industrial managed DIN-rail Ethernet switch with 8 × 10/100/1000Base-T full-gigabit copper ports. It offers full management — QoS, VLAN, IGMP Snooping/GMRP, Port Trunking, SNMP v1/v2/v3 — and multiple ring-redundancy protocols (STP/RSTP/MSTP/ERPS) for high reliability and interoperability. Its wide-temperature, EMC-hardened design meets demanding industrial field conditions, ideal for building fully-gigabit self-healing ring networks.

Key Features

  • 8 × 10/100/1000Base-T full-gigabit copper ports
  • Selectable DC 24V / 48V or AC 220V power input
  • Redundancy: STP / RSTP / MSTP / ERPS / ZJRing
  • Management: QoS, VLAN, IGMP Snooping / GMRP
  • DIN-rail or wall mounting
  • Wide operating temperature -40 ~ +75°C
  • IP40 ingress protection

Specifications

IEEE Standards

IEEE802.310BaseT Ethernet
IEEE802.3u100Base-T(X) & 100Base-FX Fast Ethernet
IEEE802.3ab1000Base-T(X) Ethernet
IEEE802.3xFlow Control
IEEE802.3dSpanning Tree Protocol
IEEE802.1wRapid Spanning Tree Protocol
IEEE802.1sMultiple Spanning Tree Protocol
ITU-T G.8032Ethernet Ring Protection Switching (ERPS)
IEEE802.1pClass of Service
IEEE802.1QVLAN Tag
IEEE802.3adLACP (Link Aggregation)
IEEE802.1xUser Authentication
IEEE802.1abLLDP

Switching

MAC Address Table8K
Packet Buffer4 Mbit
ForwardingStore-and-forward

Interfaces

RJ45 Ports8 × 10/100/1000Base-T
LED IndicatorsPower, Link, Status
ConsoleRS-232, RJ45, 9600bps, 8/N/1

Power

DC 24V Input4-pin terminal, dual redundant; 12–36 VDC
DC 48V Input4-pin terminal, dual redundant; 36–56 VDC
AC 220V Input4-pin terminal, single input; 100–240 VAC
Power ConsumptionMax 10 W
Power ProtectionReverse-polarity & overload
Alarm2-pin relay terminal

Environment

Standard Temp-10 ~ +60°C
Wide Temp-40 ~ +75°C
Storage Temp-40 ~ +85°C
Humidity5–95% non-condensing

Certification

EMCCE, FCC
EMIFCC Part 15, EN 55032 (CISPR 32) Class A
EMSEN61000-4-2/3/4/5/6/8 Level 3
ShockIEC60068-2-27
Free FallIEC60068-2-32
VibrationIEC60068-2-6
GreenRoHS, WEEE

Software Features

MIBRFC1215, RFC1213 MIB-II, RFC1157 SNMP-MIB, RFC1493 Bridge-MIB, RFC2674 VLAN-MIB, RFC1643, RFC1757, RSTP-MIB, Private MIB, LLDP-MIB
ManagementSNMP v1/v2/v3; Web, Telnet, serial CLI; DHCP client; login password
SecurityACL L2–L4 filtering; port MAC filtering; MAC binding; 802.1X; RADIUS; DDoS self-defense
VLANPort & 802.1Q VLAN; up to 4094 VLANs (VID 1–4094); management VLAN
Link AggregationStatic LACP; 2 groups × up to 4 ports
Ring RedundancySTP/RSTP/MSTP; ERPS (G.8032); ZJRing self-healing ring <50ms
QoS4 priority classes (absolute / relative scheduling), mapped by 802.1p/DSCP into 8 hardware queues per port
Port MirroringOne-way & two-way port mirroring
IGMP MulticastIGMP Snooping v1/v2; up to 256 groups
Rate LimitingIngress/egress limiting, min 64 Kbps
Storm SuppressionBroadcast, multicast & unknown-unicast
MaintenanceSyslog, RMON, Ping, LLDP
SNTPSNTP supported
FirmwareWeb & serial TFTP upgrade
Config FileImport / export supported

Physical

HousingIP40 metal enclosure
MountingDIN-rail (default), wall-mount optional
Dimensions47 (W) × 175 (H) × 150 (D) mm

Reliability

MTBF320,000 hours
Warranty5 years

Models & Ordering

ModelProduct DescriptionPrice
ZJIES3000D-8GT-ACIndustrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T copper ports, AC 220V (100–240 VAC) power.✆ WhatsApp
ZJIES3000D-8GT-DCLIndustrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T copper ports, DC 24V (12–36 VDC) with redundant power input.✆ WhatsApp
ZJIES3000D-8GT-DCHIndustrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T copper ports, DC 48V (36–56 VDC) with redundant power input.✆ WhatsApp

All three variants share identical switching specs and differ only in power input (AC 220V / DC 24V / DC 48V).

Dimensions

ZJIES3000D-8GT dimensions drawing in mm
unit: mm
Your Brand. Factory-Direct Supply.Neutral casing, ready for your logo · Protocol-level customization · Small batches welcome.
Custom & OEM →

Who uses it, where it goes and how to install it

Written for the ZJIES3000D-8GT from the manufacturer's datasheet: managed L2, 8 × Gigabit copper ports and no fiber, STP/RSTP/MSTP/ERPS/ZJRing rings, 10 W maximum, AC 220V or redundant DC 24V/48V, -40 to +75°C wide-temperature version.

Who it is for

  • Machine builders and production lines — Control cabinets that sit within 100 m of each other: 8 Gigabit copper ports connect PLCs, HMIs, drives and cameras, and the cabinets can be joined in a copper ring with no fiber or SFP modules to buy.
  • Plant rooms, tunnels and DC-powered sites — The -DCL (12–36 VDC) and -DCH (36–56 VDC) versions take two redundant inputs, and at 10 W maximum the switch adds very little load to a battery system.
  • Edge switch on a fiber ring — Hang it off a port of a ZJIES3000D-8GT2GB or -8GT4GB ring node when one cabinet needs more copper ports; VLANs, QoS and SNMP stay the same across the network.
  • Buildings and campus CCTV — Floor or riser cabinets within 100 m of each other; IGMP Snooping (256 groups) keeps multicast video to the ports that need it, and 4094 VLANs separate cameras from office traffic.

Where and how to install

  • DIN rail inside a cabinet — The fanless metal housing is IP40, so outdoors it must sit inside a sealed cabinet. Mount it on the DIN rail (default) or the optional wall bracket, leave room below the RJ45 ports for the cable bend and label which two ports form the ring.
  • Power wiring and redundancy — Order -AC for 100–240 VAC (single input), -DCL for 12–36 VDC or -DCH for 36–56 VDC. On DC versions feed both inputs of the 4-pin terminal from separate supplies or breakers. At 10 W maximum it draws about 0.42 A at 24 V or 0.21 A at 48 V.
  • Use the alarm terminal — Wire the 2-pin alarm terminal to a PLC input, RTU or warning lamp so a fault is seen locally even when the network is down. The datasheet does not list which events trigger it; set the alarm conditions in the web interface and test by removing one power input.
  • Copper ring links, earthing and surge — Every ring link is copper, so keep each hop under 100 m on Cat5e or Cat6, use shielded outdoor cable between buildings and add Ethernet surge protectors at both ends of any link that leaves a building. Bond the cabinets and DIN rails to earth; the switch's EN61000-4-5 Level 3 surge rating does not cover lightning on a long outdoor run.
  • Temperature and condensation — There are two versions: standard -10~60°C and wide -40~75°C; specify the wide one for unheated outdoor cabinets. Humidity is 5–95% non-condensing, so add a filtered vent or small heater and bring cables in from the bottom through sealed glands.

Power versions and copper ring planning

All three versions have the same 8 copper ports and software; only the power input differs. In a ring, 2 of the 8 ports carry the ring, leaving 6 for devices. Plan as if one link is broken: with 6 cameras per switch at an assumed 8 Mbps each, every node adds 48 Mbps, so about 14 nodes (84 cameras, 672 Mbps) stay under about 70% of a 1000 Mbps link, with no more than 100 m between neighbours.

ZJIES3000D-8GT-ACZJIES3000D-8GT-DCLZJIES3000D-8GT-DCH
Power input100–240 VAC, single input12–36 VDC, dual redundant36–56 VDC, dual redundant
Current at max. load≈0.05 A at 220 V≈0.42 A at 24 V≈0.21 A at 48 V
Copper ports8 × 10/100/1000Base-T8 × 10/100/1000Base-T8 × 10/100/1000Base-T
Ports free for devices in a ring666
Fiber portsNoneNoneNone
Max. distance between ring nodes100 m (copper)100 m (copper)100 m (copper)
Ring protocolsSTP/RSTP/MSTP, ERPS, ZJRingSTP/RSTP/MSTP, ERPS, ZJRingSTP/RSTP/MSTP, ERPS, ZJRing
ZJRing self-healing time<50 ms<50 ms<50 ms
Max. power10 W10 W10 W
Operating temperature-10~60°C or -40~75°C-10~60°C or -40~75°C-10~60°C or -40~75°C
  • Pick -DCH for a 48V DC battery system (36–56 VDC) and -DCL for a 24V DIN-rail supply or 12V/24V battery (12–36 VDC); both take two supplies for redundancy.
  • Pick -AC where mains is the only supply; it has one input, so use a UPS for backup.
  • Any hop over 100 m, between buildings with different earths, or along a road? Use the ZJIES3000D-8GT2GB (2 SFP) or ZJIES3000D-8GT4GB (4 SFP) for fiber links instead.

Ports, power ranges, 10 W, ring protocols, <50 ms (ZJRing) and temperature are from the manufacturer's datasheet. Current = 10 W ÷ voltage. 100 m is the standard copper Ethernet limit. Ring figures assume 8 Mbps per camera, 6 cameras per node and a 70% load ceiling; the datasheet gives no maximum node count per ring.

8-Port Gigabit DIN-Rail Switch FAQ — ZJIES3000D-8GT

How many ports does the ZJIES3000D-8GT have, and are any of them fiber?
It provides 8 x 10/100/1000Base-T gigabit copper RJ45 ports; the spec sheet lists no SFP fiber slots, making it the all-copper unit of this series. All ports run full gigabit with store-and-forward switching, an 8K MAC address table and a 4 Mbit packet buffer.
What power inputs can I use on site?
Three options are listed: dual-redundant DC 24V (12-36 VDC), dual-redundant DC 48V (36-56 VDC), or a single AC 220V input (100-240 VAC), all on 4-pin terminals. Maximum draw is only 10 W, with reverse-polarity and overload protection plus a 2-pin relay alarm terminal.
Can I build a redundant ring with this switch?
Yes. It supports STP, RSTP and MSTP spanning-tree plus ERPS ring protection per ITU-T G.8032, so you can close a loop of switches and the network recovers automatically if one link fails — the series is designed for fully gigabit self-healing ring networks.
What environmental conditions does it tolerate?
Operating range is -10 to +60 C standard or -40 to +75 C wide-temperature, storage -40 to +85 C, humidity 5-95% non-condensing. It passes EN61000-4-2/3/4/5/6/8 Level 3 EMC immunity and IEC60068-2 shock, free-fall and vibration tests, so it suits cabinets near motors and drives.
Is the ZJIES3000D-8GT a managed switch?
Yes — full management via SNMP v1/v2/v3, web, Telnet and a serial CLI console (RS-232, RJ45, 9600 bps). Features include QoS, port and 802.1Q VLANs up to 4094 IDs, IGMP Snooping, LACP port trunking, ACL L2-L4 filtering, 802.1X with RADIUS and DDoS self-defense.
How far apart can ZJIES3000D-8GT ring nodes be without fiber?
Up to 100 m per hop, because the ring runs over the copper ports and 100 m is the Ethernet limit for Cat5e/Cat6 copper. The switch has no SFP or fiber port, so there is no way to stretch a hop on this model. For longer hops, links between buildings or roadside runs, use the ZJIES3000D-8GT2GB or ZJIES3000D-8GT4GB, which have the same software plus SFP slots, and keep the 8GT for cabinets that are close together.
How many cameras or PLCs can a ring of ZJIES3000D-8GT switches handle?
Each switch keeps 6 ports for devices after 2 are used for the ring. For video, plan on one 1000 Mbps link carrying everything when the ring is broken: at an assumed 8 Mbps per 4 MP camera, 6 cameras add 48 Mbps per node, so about 14 nodes (84 cameras, 672 Mbps) stay under about 70% load. PLC and HMI traffic is tiny by comparison, so for control networks the port count, not the bandwidth, is the limit; give control traffic a higher QoS priority if cameras share the ring. The switch has no PoE, so cameras need local power or PoE injectors.
Do I need the managed ZJIES3000D-8GT or is the unmanaged ZJIES1000D-8GT enough?
Choose the managed 3000D-8GT if you need any of these: a self-healing ring (ERPS, ZJRing, RSTP/MSTP), VLANs to separate cameras, PLCs and office traffic, IGMP Snooping for multicast video, SNMP monitoring with an alarm terminal, or 802.1X/ACL security. An unmanaged switch has none of these, so a cabled loop between unmanaged switches causes a broadcast storm. For a single standalone cabinet with a few devices and no ring, the unmanaged ZJIES1000D-8GT is the simpler choice.
Can the ZJIES3000D-8GT join an ERPS ring with switches from other brands?
Yes, use ERPS (ITU-T G.8032) or RSTP/MSTP for a mixed-brand ring, because these are standard protocols. ZJRing is Zhongxin's own protocol and only runs between Zhongxin switches; the <50 ms self-healing time in the datasheet is stated for ZJRing. For ERPS, every switch needs the same ring ID, control VLAN and ring ports, with exactly one RPL owner. Recovery time in a mixed ring depends on all devices, so unplug a ring link and check before handover; send us the other brand's model and we will check the settings with you.
How do I set up the ZJIES3000D-8GT the first time and monitor it remotely?
Connect a console cable to the RJ45 console port (RS-232, 9600 bps, 8 data bits, no parity, 1 stop bit), or use the web interface or Telnet over the network; the default IP address and login are not on our page, so we send them with the order. For remote monitoring it supports SNMP v1/v2/v3 with traps, Syslog, RMON and LLDP, plus the 2-pin alarm terminal for a hard-wired alarm. After commissioning, export the configuration file so a spare unit can be loaded with the same settings, and set SNTP so log times are correct.
What power connector does the ZJIES3000D-8GT have, and do I need to confirm it before ordering?
Yes, please confirm the power connector with us before ordering. For Zhongxin Shutong products the power input type and connector can differ between versions and batches, so tell us your supply (AC or DC and the voltage), how you will wire it in the cabinet and your country's plug standard, and we confirm the exact connector and supply version of the ZJIES3000D-8GT for your order.

Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.

Our own line — Zhongxin Shutong industrial switches1,500 m² clean rooms100% port-by-port tested-40…+75 °C rated, cycled to +85 °CEN 61000-4 Level 3 EMC immunitySerial-number traceability on every unitISO 9001 · 14001 · 27001 · CMMI L3See the factory →See all certifications →

Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA

Request a quote for this product

An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.

Product: ZJIES3000D-8GT

For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.

Or ask on WhatsApp

Zhengzhou Huamai Information Technology Co., Ltd. · Tel / WhatsApp +86 186 1168 3168 · info@atlascommtech.com