ZJIES3000D-8GT2GB
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIES3000D-8GT2GB is an industrial managed DIN-rail Ethernet switch with 8 × 10/100/1000Base-T ports and 2 × 1000Base-X SFP fiber slots. It offers full management — QoS, VLAN, IGMP Snooping/GMRP, Port Trunking, SNMP v1/v2/v3 — and multiple ring-redundancy protocols (STP/RSTP/MSTP/ERPS) for high reliability and interoperability. Its wide-temperature, EMC-hardened design meets demanding industrial field conditions, ideal for building fully-gigabit self-healing ring networks.
Key Features
- 8 × 10/100/1000Base-T + 2 × 1000Base-X SFP fiber slots
- Selectable DC 24V / 48V or AC 220V power input
- Redundancy: STP / RSTP / MSTP / ERPS / ZJRing
- Management: QoS, VLAN, IGMP Snooping / GMRP
- DIN-rail or wall mounting
- Wide operating temperature -40 ~ +75°C
- IP40 ingress protection
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100Base-T(X) & 100Base-FX Fast Ethernet |
| IEEE802.3ab | 1000Base-T(X) Ethernet |
| IEEE802.3z | 1000Base-X Ethernet |
| IEEE802.3x | Flow Control |
| IEEE802.3d | Spanning Tree Protocol |
| IEEE802.1w | Rapid Spanning Tree Protocol |
| IEEE802.1s | Multiple Spanning Tree Protocol |
| ITU-T G.8032 | Ethernet Ring Protection Switching (ERPS) |
| IEEE802.1p | Class of Service |
| IEEE802.1Q | VLAN Tag |
| IEEE802.3ad | LACP (Link Aggregation) |
| IEEE802.1x | User Authentication |
| IEEE802.1ab | LLDP |
Switching
| MAC Address Table | 8K |
| Packet Buffer | 4 Mbit |
| Forwarding | Store-and-forward |
Interfaces
| RJ45 Ports | 8 × 10/100/1000Base-T |
| SFP Fiber | 2 × 1000Base-X SFP slots |
| LED Indicators | Power, Link, Fiber, Status |
| Console | RS-232, RJ45, 9600bps, 8/N/1 |
Power
| DC 24V Input | 4-pin terminal, dual redundant; 12–36 VDC |
| DC 48V Input | 4-pin terminal, dual redundant; 36–56 VDC |
| AC 220V Input | 4-pin terminal, single input; 100–240 VAC |
| Power Consumption | Max 15 W |
| Power Protection | Reverse-polarity & overload |
| Alarm | 2-pin relay terminal |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2/3/4/5/6/8 Level 3 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Software Features
| MIB | RFC1215, RFC1213 MIB-II, RFC1157 SNMP-MIB, RFC1493 Bridge-MIB, RFC2674 VLAN-MIB, RFC1643, RFC1757, RSTP-MIB, Private MIB, LLDP-MIB |
| Management | SNMP v1/v2/v3; Web, Telnet, serial CLI; DHCP client; login password |
| Security | ACL L2–L4 filtering; port MAC filtering; MAC binding; 802.1X; RADIUS; DDoS self-defense |
| VLAN | Port & 802.1Q VLAN; up to 4094 VLANs (VID 1–4094); management VLAN |
| Link Aggregation | Static LACP; 2 groups × up to 4 ports |
| Ring Redundancy | STP/RSTP/MSTP; ERPS (G.8032); ZJRing self-healing ring <50ms |
| QoS | 4 priority classes (absolute / relative scheduling), mapped by 802.1p/DSCP into 8 hardware queues per port |
| Port Mirroring | One-way & two-way port mirroring |
| IGMP Multicast | IGMP Snooping v1/v2; up to 256 groups |
| Rate Limiting | Ingress/egress limiting, min 64 Kbps |
| Storm Suppression | Broadcast, multicast & unknown-unicast |
| Maintenance | Syslog, RMON, Ping, LLDP |
| SNTP | SNTP supported |
| Firmware | Web & serial TFTP upgrade |
| Config File | Import / export supported |
Physical
| Housing | IP40 metal enclosure |
| Mounting | DIN-rail (default), wall-mount optional |
| Dimensions | 47 (W) × 175 (H) × 150 (D) mm |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIES3000D-8GT2GB-AC | Industrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T, 2 × 1000Base-X SFP fiber slots, AC 220V (100–240 VAC) power. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional. | |
| ZJIES3000D-8GT2GB-DCL | Industrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T, 2 × 1000Base-X SFP fiber slots, DC 24V (12–36 VDC) with redundant power input. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional. | |
| ZJIES3000D-8GT2GB-DCH | Industrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T, 2 × 1000Base-X SFP fiber slots, DC 48V (36–56 VDC) with redundant power input. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional. |
Standard package does not include SFP optical modules.
Dimensions

Who uses it, where it goes and how to install it
Written for the ZJIES3000D-8GT2GB from the manufacturer's datasheet: managed L2, 8 × Gigabit copper + 2 × 1000Base-X SFP slots, STP/RSTP/MSTP/ERPS/ZJRing rings, 15 W maximum, AC 220V or redundant DC 24V/48V, -40 to +75°C wide-temperature version.
Who it is for
- City, road and perimeter CCTV rings — The standard fiber-ring node: up to 8 cameras or devices per cabinet on Gigabit copper, and the 2 SFP ports run one fiber each way round the ring, so a cut fiber or a failed cabinet does not take the rest of the ring down.
- Traffic and ITS cabinets — Junction cabinets with a signal controller, detectors, an ANPR or speed camera and a few overview cameras; multimode SFP reaches 2 km and single-mode 10 km to the next junction.
- Substations, plants and pipelines — -DCH runs on a 48V DC battery system (36–56 VDC) with two redundant inputs, the 2-pin alarm terminal and SNMP traps report faults, and fiber between buildings avoids earth-potential problems on copper.
- Integrators upgrading unmanaged chains — Same 8 + 2 port layout as the unmanaged ZJIES1000D-8GT2GB, so an existing daisy chain can be closed into a ring by swapping the cabinet switches and adding one fiber from the last cabinet back to the control room.
Where and how to install
- DIN rail inside a sealed cabinet — The fanless metal housing is IP40, so outdoors it must sit inside a sealed cabinet. Mount it on the DIN rail (default) or the optional wall bracket, with the SFP ports facing the fiber splice tray and space below for the cable bend.
- Power wiring and redundancy — Order -AC for 100–240 VAC (single input), -DCL for 12–36 VDC or -DCH for 36–56 VDC. On DC versions feed both inputs of the 4-pin terminal from separate supplies or breakers. At 15 W maximum it draws about 0.63 A at 24 V or 0.31 A at 48 V.
- Plan the ports before you terminate — Use SFP 1 and SFP 2 as the two ring ports on every node and the 8 copper ports for cameras and field devices. Put the NVR and VMS on the control-room node, use the same ring protocol on every node (with ERPS, exactly one RPL owner), and label each fiber with the cabinet it goes to.
- Earthing, surge and copper runs — Bond the cabinet and DIN rail to earth. The switch is tested to EN61000-4-5 surge at Level 3, which does not cover a lightning hit on the pole: add Ethernet surge protectors on copper runs that leave the cabinet and keep each run under 100 m. Fiber between cabinets carries no surge.
- Temperature and condensation — There are two versions: standard -10~60°C and wide -40~75°C; specify the wide one for unheated outdoor cabinets. Humidity is 5–95% non-condensing, so add a filtered vent or small heater, bring cables in from the bottom and keep dust caps on unused SFP slots.
Power versions and ring planning
All three versions have the same 8 + 2 port layout and software; only the power input differs. Plan the ring as if one link is broken and all traffic runs one way: with 8 cameras per switch at an assumed 8 Mbps each, every node adds 64 Mbps, so about 10 nodes (80 cameras, 640 Mbps) stay under about 70% of the 1000 Mbps fiber. For more cameras, build a second ring back to the control room.
| ZJIES3000D-8GT2GB-AC | ZJIES3000D-8GT2GB-DCL | ZJIES3000D-8GT2GB-DCH | |
|---|---|---|---|
| Power input | 100–240 VAC, single input | 12–36 VDC, dual redundant | 36–56 VDC, dual redundant |
| Current at max. load | ≈0.07 A at 220 V | ≈0.63 A at 24 V | ≈0.31 A at 48 V |
| Copper ports | 8 × 10/100/1000Base-T | 8 × 10/100/1000Base-T | 8 × 10/100/1000Base-T |
| Fiber ports | 2 × 1000Base-X SFP (modules extra) | 2 × 1000Base-X SFP (modules extra) | 2 × 1000Base-X SFP (modules extra) |
| SFP module options | MM 2 km / SM 10 km, single or dual fiber | MM 2 km / SM 10 km, single or dual fiber | MM 2 km / SM 10 km, single or dual fiber |
| Ring protocols | STP/RSTP/MSTP, ERPS, ZJRing | STP/RSTP/MSTP, ERPS, ZJRing | STP/RSTP/MSTP, ERPS, ZJRing |
| ZJRing self-healing time | <50 ms | <50 ms | <50 ms |
| Cameras per ring at 8 Mbps (planning) | ≈80 (10 nodes × 8) | ≈80 (10 nodes × 8) | ≈80 (10 nodes × 8) |
| Max. power | 15 W | 15 W | 15 W |
| Operating temperature | -10~60°C or -40~75°C | -10~60°C or -40~75°C | -10~60°C or -40~75°C |
- Pick -DCH for substations, telecom rooms and any site with a 48V DC battery bank (36–56 VDC).
- Pick -DCL for cabinets with a 24V DIN-rail supply or a 12V/24V battery system (12–36 VDC), with two supplies for redundancy.
- Pick -AC only where mains is the one supply available: it has a single input, so a UPS is the backup. Need two more fiber directions from one cabinet? Use the ZJIES3000D-8GT4GB.
Ports, power ranges, 15 W, ring protocols, <50 ms (ZJRing) and temperature are from the manufacturer's datasheet; fiber distances are from the ordering table. Current = 15 W ÷ voltage. Ring figures assume 8 Mbps per camera, 8 cameras per node and a 70% load ceiling; the datasheet gives no maximum node count per ring.
Gigabit DIN-Rail Switch FAQ — ZJIES3000D-8GT2GB
What is the port layout of the ZJIES3000D-8GT2GB?
What are the 2 SFP slots used for?
Which power supplies does it accept?
Does it support ring redundancy for critical networks?
What temperature range and management options does it offer?
What do I gain with the managed ZJIES3000D-8GT2GB over the unmanaged ZJIES1000D-8GT2GB?
Can the ZJIES3000D-8GT2GB power my IP cameras over PoE?
How many cameras can a ring of ZJIES3000D-8GT2GB switches carry back to the NVR?
Which SFP modules should I order for the ZJIES3000D-8GT2GB?
Can the ZJIES3000D-8GT2GB join an ERPS ring with switches from other brands?
What power connector does the ZJIES3000D-8GT2GB have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIES3000D-8GT2GB
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.