Skip to main content
Home › Industrial Switches › ZJIES3000D-8GT8GB

ZJIES3000D-8GT8GB

Industrial · Managed L2
Managed DIN-Rail Industrial Ethernet Switch · 8×GE + 8×SFP
Project-Based Pricing
Volume & combo discounts — get your quote
In-stock models: 3 days to your forwarder's warehouse in China after payment · Out-of-stock: 7–15 working days · then air 5–10 days or sea 25–45 days to your port
✓ Project-level customization & OEM supported
Get Best Price on WhatsAppRequest a quote ↓

Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA

Need the PDF datasheet? Get it on WhatsApp →
How to get a better price
Volume DiscountOrder 50+ pcs of this model
CONTACT US
Project Combo DiscountMix any categories & models storewide in one order — no quantity limit
BIGGER
Verified Project DiscountDistributor, integrator or end user with a real project? Send the BOQ — project pricing plus free system design. Partner projects are protected: we never quote your end customer behind you
BIGGEST
All discounts are quoted personally — message me on WhatsApp ↑
◆-40 ~ 75°C
◆IP40 Fanless
◆Ring Self-Heal <10ms
◆4094 VLANs
◆5-Year Warranty

Overview

The ZJIES3000D-8GT8GB is an industrial managed DIN-rail Ethernet switch with 8 × 10/100/1000Base-T ports and 8 × 1000Base-X SFP fiber slots. It offers full management — QoS, VLAN, IGMP Snooping/GMRP, Port Trunking, SNMP v1/v2/v3 — and multiple ring-redundancy protocols (STP/RSTP/MSTP/ERPS) for high reliability and interoperability. Its wide-temperature, EMC-hardened design meets demanding industrial field conditions, ideal for building fully-gigabit self-healing ring networks.

Key Features

  • 8 × 10/100/1000Base-T + 8 × 1000Base-X SFP fiber slots
  • Selectable DC 24V / 48V or AC 220V power input
  • Redundancy: STP / RSTP / MSTP / ERPS / ZJRing
  • Management: QoS, VLAN, IGMP Snooping / GMRP
  • DIN-rail or wall mounting
  • Wide operating temperature -40 ~ +75°C
  • IP40 ingress protection

Specifications

IEEE Standards

IEEE802.310BaseT Ethernet
IEEE802.3u100Base-T(X) & 100Base-FX Fast Ethernet
IEEE802.3ab1000Base-T(X) Ethernet
IEEE802.3z1000Base-X Ethernet
IEEE802.3xFlow Control
IEEE802.3dSpanning Tree Protocol
IEEE802.1wRapid Spanning Tree Protocol
IEEE802.1sMultiple Spanning Tree Protocol
ITU-T G.8032Ethernet Ring Protection Switching (ERPS)
IEEE802.1pClass of Service
IEEE802.1QVLAN Tag
IEEE802.3adLACP (Link Aggregation)
IEEE802.1xUser Authentication
IEEE802.1abLLDP

Switching

MAC Address Table8K
Packet Buffer4 Mbit
ForwardingStore-and-forward

Interfaces

RJ45 Ports8 × 10/100/1000Base-T
SFP Fiber8 × 1000Base-X SFP slots
LED IndicatorsPower, Link, Fiber, Status
ConsoleRS-232, RJ45, 9600bps, 8/N/1

Power

DC 24V Input4-pin terminal, dual redundant; 12–36 VDC
DC 48V Input4-pin terminal, dual redundant; 36–56 VDC
AC 220V Input4-pin terminal, single input; 100–240 VAC
Power ConsumptionMax 15 W
Power ProtectionReverse-polarity & overload
Alarm2-pin relay terminal

Environment

Standard Temp-10 ~ +60°C
Wide Temp-40 ~ +75°C
Storage Temp-40 ~ +85°C
Humidity5–95% non-condensing

Certification

EMCCE, FCC
EMIFCC Part 15, EN 55032 (CISPR 32) Class A
EMSEN61000-4-2/3/4/5/6/8 Level 3
ShockIEC60068-2-27
Free FallIEC60068-2-32
VibrationIEC60068-2-6
GreenRoHS, WEEE

Software Features

MIBRFC1215, RFC1213 MIB-II, RFC1157 SNMP-MIB, RFC1493 Bridge-MIB, RFC2674 VLAN-MIB, RFC1643, RFC1757, RSTP-MIB, Private MIB, LLDP-MIB
ManagementSNMP v1/v2/v3; Web, Telnet, serial CLI; DHCP client; login password
SecurityACL L2–L4 filtering; port MAC filtering; MAC binding; 802.1X; RADIUS; DDoS self-defense
VLANPort & 802.1Q VLAN; up to 4094 VLANs (VID 1–4094); management VLAN
Link AggregationStatic LACP; 2 groups × up to 4 ports
Ring RedundancySTP/RSTP/MSTP; ERPS (G.8032); ZJRing self-healing ring <10ms
QoS4 priority classes (absolute / relative scheduling), mapped by 802.1p/DSCP into 8 hardware queues per port
Port MirroringOne-way & two-way port mirroring
IGMP MulticastIGMP Snooping v1/v2; up to 256 groups
Rate LimitingIngress/egress limiting, min 64 Kbps
Storm SuppressionBroadcast, multicast & unknown-unicast
MaintenanceSyslog, RMON, Ping, LLDP
SNTPSNTP supported
FirmwareWeb & serial TFTP upgrade
Config FileImport / export supported

Physical

HousingIP40 metal enclosure
MountingDIN-rail (default), wall-mount optional
Dimensions50 (W) × 175 (H) × 146 (D) mm

Reliability

MTBF320,000 hours
Warranty5 years

Models & Ordering

ModelProduct DescriptionPrice
ZJIES3000D-8GT8GB-ACIndustrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T, 8 × 1000Base-X SFP fiber slots, AC 220V (100–240 VAC) power. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional.✆ WhatsApp
ZJIES3000D-8GT8GB-DCLIndustrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T, 8 × 1000Base-X SFP fiber slots, DC 24V (12–36 VDC) with redundant power input. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional.✆ WhatsApp
ZJIES3000D-8GT8GB-DCHIndustrial managed DIN-rail Ethernet switch — 8 × 10/100/1000Base-T, 8 × 1000Base-X SFP fiber slots, DC 48V (36–56 VDC) with redundant power input. Multimode dual-fiber 2 km / single-mode dual-fiber 10 km, single- or dual-fiber optional.✆ WhatsApp

Standard package does not include SFP optical modules.

Dimensions

ZJIES3000D-8GT8GB dimensions drawing in mm
unit: mm
Your Brand. Factory-Direct Supply.Neutral casing, ready for your logo · Protocol-level customization · Small batches welcome.
Custom & OEM →

Who uses it, where it goes and how to install it

Written for the ZJIES3000D-8GT8GB from the manufacturer's datasheet: managed Layer 2, 8 × Gigabit copper + 8 × 1000Base-X SFP slots, STP/RSTP/MSTP/ERPS and ZJRing (<10 ms), AC 220V or redundant DC 24V/48V, -40 to +75°C.

Who it is for

  • Fiber hub cabinets on CCTV and ITS projects — With 8 SFP slots, one cabinet can terminate fiber runs from several remote poles or junction boxes and hand the traffic to the control room over the remaining fiber ports, while the 8 copper ports serve local cameras and devices.
  • Substations, power plants and utilities — The -DCH version runs from a 48V DC station supply (36–56 VDC) with two redundant inputs, and the EMS tests are listed at Level 3 for ESD, surge and fast transients; fiber between buildings avoids ground-potential problems.
  • Factories, mines and oil & gas sites — VLANs (up to 4094), 802.1p/DSCP QoS and ACL filtering keep PLC, SCADA and camera traffic apart on one fiber backbone, and the -40 to +75°C wide-temperature version suits unheated cabinets.
  • System integrators building redundant rings — ZJRing heals in under 10 ms between Zhongxin switches, and standard ERPS (G.8032), RSTP and MSTP are there for rings or links that include other brands; SNMP v1/v2/v3, Syslog and the relay alarm let the control room see a broken link.

Where and how to install

  • DIN rail in a sealed cabinet — The metal housing is IP40, so outdoors it must sit inside a sealed cabinet. Mount it on the DIN rail (default) or the optional wall bracket, about 50 mm of rail width, with the 8 SFP ports facing a fiber splice tray or patch panel and enough space for gentle fiber bends.
  • SFP modules are ordered separately — The standard package does not include SFP optical modules. Choose 1000Base-X modules per link: multimode dual-fiber for up to 2 km, single-mode dual-fiber for up to 10 km, or single-fiber (BiDi) modules used as a matched pair at both ends. Keep dust caps on unused slots.
  • Power wiring and alarm relay — Order -AC for 100–240 VAC (single input), -DCL for 12–36 VDC or -DCH for 36–56 VDC; on DC versions feed both inputs of the 4-pin terminal from separate supplies or breakers. At the 15 W maximum the switch draws about 0.63 A at 24 V or 0.31 A at 48 V. Wire the 2-pin relay terminal to the cabinet alarm input.
  • Earthing, surge and copper runs — Bond the cabinet and DIN rail to earth. Keep each copper run under 100 m and fit Ethernet surge protectors on copper lines that leave the cabinet to another pole or building; use fiber for anything longer or between separately earthed sites.
  • Temperature, condensation and airflow — Order the wide-temperature version (-40 to +75°C) for outdoor cabinets; the standard version is -10 to +60°C. Humidity is 5–95% non-condensing, so in cabinets with hot days and cold nights add a filtered vent or small heater and bring cables in from the bottom. The housing is fanless, so leave space above and below it.

Ports & ring planning: -AC, -DCL or -DCH

All three versions have the same 8 copper ports, 8 SFP slots and software; only the power input differs. In a ring, plan for the case where one fiber is cut and all traffic returns on one 1000 Mbps link: at an assumed 8 Mbps per 4 MP camera and a 70% load ceiling, one ring carries about 85 cameras.

ZJIES3000D-8GT8GB-ACZJIES3000D-8GT8GB-DCLZJIES3000D-8GT8GB-DCH
Copper ports8 × 10/100/1000Base-T8 × 10/100/1000Base-T8 × 10/100/1000Base-T
Fiber ports8 × 1000Base-X SFP8 × 1000Base-X SFP8 × 1000Base-X SFP
Power input100–240 VAC12–36 VDC36–56 VDC
Redundant inputNo (single)Yes (dual)Yes (dual)
Max. power / current15 W15 W ≈ 0.63 A @ 24 V15 W ≈ 0.31 A @ 48 V
Ring protocolsSTP/RSTP/MSTP, ERPS, ZJRingSTP/RSTP/MSTP, ERPS, ZJRingSTP/RSTP/MSTP, ERPS, ZJRing
ZJRing recovery<10 ms<10 ms<10 ms
Link aggregation2 groups × 4 ports2 groups × 4 ports2 groups × 4 ports
SFP reach (by module)MM 2 km / SM 10 kmMM 2 km / SM 10 kmMM 2 km / SM 10 km
Operating temperature-10~60°C / -40~75°C-10~60°C / -40~75°C-10~60°C / -40~75°C
Size (W × H × D)50 × 175 × 146 mm50 × 175 × 146 mm50 × 175 × 146 mm
  • Pick -DCH for substations and telecom sites with a 48V DC battery system, -DCL for 24V DC control cabinets, and -AC only where mains is the only supply.
  • Use 2 SFP slots for the ring and the other 6 for spur fibers to remote poles; or bundle up to 4 fiber ports in one aggregation group when a single 1000 Mbps link to the control room is not enough.
  • Pick the ZJIES3000D-8GT2GB instead if a cabinet only needs the two ring fibers and no spur fibers.

Ports, power, protocols, aggregation, temperature and size are from the manufacturer's datasheet; reach is per module type (modules not included). Current = 15 W ÷ voltage. 85 cameras ≈ 70% × 1000 Mbps ÷ 8 Mbps per camera (assumption).

Fiber DIN-Rail Switch FAQ — ZJIES3000D-8GT8GB

What makes the ZJIES3000D-8GT8GB different from other models in the line?
Its port mix: 8 x 10/100/1000Base-T copper ports plus 8 x 1000Base-X SFP fiber slots on one DIN-rail unit — sixteen gigabit interfaces, half of them fiber. That suits sites where many fiber runs converge on a single cabinet while local devices stay on copper.
Can it aggregate several fiber links into one cabinet?
Yes — with 8 x 1000Base-X SFP slots it can terminate up to eight gigabit fiber links, for example runs arriving from separate buildings or along a corridor, while its 8 copper ports serve local equipment. LACP link aggregation and 802.1Q VLANs help organize that traffic.
What power inputs does the ZJIES3000D-8GT8GB take?
Dual-redundant DC 24V (12-36 VDC), dual-redundant DC 48V (36-56 VDC) or a single AC 220V input (100-240 VAC), all on 4-pin terminals. It draws at most 15 W and includes reverse-polarity and overload protection plus a 2-pin relay alarm terminal for fault reporting.
Does it support self-healing ring topologies?
Yes. STP, RSTP and MSTP spanning-tree plus ERPS per ITU-T G.8032 are built in, and the series is designed for fully gigabit self-healing rings. With eight SFP slots, one unit can even participate in more than one fiber ring or add spur links beyond the ring.
What environment and management features does it offer?
Operating range is -10 to +60 C standard or -40 to +75 C wide-temperature with EN61000-4 Level 3 EMC immunity and IEC60068-2 mechanical tests. Management runs over SNMP v1/v2/v3, web, Telnet and serial CLI, with QoS, 802.1Q VLAN, IGMP Snooping, LACP and 802.1X.
Which SFP modules can I put in the ZJIES3000D-8GT8GB, and does it take 100 Mbps or 10G modules?
The 8 slots are 1000Base-X SFP, so plan 1 Gigabit modules: multimode dual-fiber up to 2 km, single-mode dual-fiber up to 10 km, or single-fiber modules as a matched pair. 10G SFP+ modules will not work. The standards list includes 100Base-FX, but the ports are specified as 1000Base-X, so if the far end is a 100 Mbps fiber device confirm with us before ordering. Modules are not in the box; tell us the fiber type, distance and far-end equipment and we match them.
Can a ring of ZJIES3000D-8GT8GB switches include switches from other brands?
Yes, if every switch in that ring runs the same standard protocol: ERPS (ITU-T G.8032), RSTP or MSTP. ZJRing, the protocol with the <10 ms self-healing time, is Zhongxin's own ring and only works between Zhongxin switches. The datasheet does not give a recovery time for ERPS or RSTP, so if your project specifies one, ask us before ordering; test the mixed ring by pulling one fiber before handover.
How many IP cameras can I put on one fiber ring of ZJIES3000D-8GT8GB switches?
Size the ring for a fiber cut, when all video returns on one 1000 Mbps link. At an assumed 8 Mbps per 4 MP camera and a 70% load ceiling that is about 85 cameras per ring (700 ÷ 8 ≈ 87). Each switch adds up to 8 copper-connected cameras plus whatever arrives on its spur fibers. For more cameras, split them into two rings or use static link aggregation (2 groups × up to 4 ports) on the links to the control room.
How do I configure the ZJIES3000D-8GT8GB the first time?
You can use the web interface from a laptop on a copper port, Telnet, or the RS-232 console (RJ45 connector, 9600 bps, 8/N/1) with a console cable. Change the login password, set the management IP or DHCP client and a management VLAN, then configure the ring before you connect the second ring fiber, so no loop forms. Export the configuration file afterwards; it can be imported to the next switch, and firmware is upgraded by web or serial TFTP.
Will multicast camera streams flood every port of the ZJIES3000D-8GT8GB?
Not if IGMP Snooping is enabled: the switch then forwards each multicast group only to the ports that joined it, for up to 256 groups (IGMP v1/v2). You also need an IGMP querier somewhere in the network, usually the core switch or router. Broadcast, multicast and unknown-unicast storm suppression and per-port rate limiting (from 64 Kbps) add protection if a device misbehaves.
What power connector does the ZJIES3000D-8GT8GB have, and do I need to confirm it before ordering?
Yes, please confirm the power connector with us before ordering. For Zhongxin Shutong products the power input type and connector can differ between versions and batches, so tell us your supply (AC or DC and the voltage), how you will wire it in the cabinet and your country's plug standard, and we confirm the exact connector and supply version of the ZJIES3000D-8GT8GB for your order.

Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.

Our own line — Zhongxin Shutong industrial switches1,500 m² clean rooms100% port-by-port tested-40…+75 °C rated, cycled to +85 °CEN 61000-4 Level 3 EMC immunitySerial-number traceability on every unitISO 9001 · 14001 · 27001 · CMMI L3See the factory →See all certifications →

Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA

Request a quote for this product

An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.

Product: ZJIES3000D-8GT8GB

For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.

Or ask on WhatsApp

Zhengzhou Huamai Information Technology Co., Ltd. · Tel / WhatsApp +86 186 1168 3168 · info@atlascommtech.com