
ZJIC200-1F2S
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIC200-1F2S is an industrial gigabit fiber-to-serial protocol converter that converts a single 1000Base-X fiber port (SC/ST/FC, single-mode or multimode) into 2 × RS232/485 serial channels for long-distance transmission of serial data over fiber. It ships in AC 220V (100–240V) single-input, DC 24V (12–36V) or DC 48V (36–56V) dual-input power variants, with reverse-polarity and overload protection, drawing a maximum of 3 W. Housed in a fanless IP40 metal enclosure (120×32×95 mm) that supports desktop, DIN-rail or wall mounting, it operates from -10 to +60°C in the standard version or -40 to +75°C in the wide-temperature version — suited for industrial sites that need to carry legacy RS232/485 serial equipment over a gigabit fiber link.
Is This the Right Fit?
Six real deployment scenarios matched to this model's actual fiber-to-serial specifications.
- Not for direct copper-Ethernet extension or camera/PoE aggregation — this model bridges 1000Base-X fiber to RS232/485 serial only; it has no RJ45 Ethernet ports.
- Not a managed switch — no VLAN, ERPS/RSTP ring redundancy or L2 management; it is a fixed point-to-point protocol converter.
- Fiber interface is fixed (1000Base-X, non-SFP) — fiber mode, connector (SC/ST/FC) and single/dual-fiber must be chosen at order time, not swapped in the field.
Key Features
- Converts 1 × 1000Base-X fiber to 2 × RS232/485 serial channels (5-pin terminal)
- Fiber port SC/ST/FC connector · single-mode/multimode · single-fiber/dual-fiber optional
- Transmission distance: multimode 2 km / single-mode 20, 40, 60 or 120 km
- AC 220V (100–240V) single input or DC 24V (12–36V)/48V (36–56V) redundant dual input
- Fanless IP40 metal enclosure · desktop/DIN-rail/wall-mount · max 3 W consumption
- Wide temperature -40 ~ +75°C (wide-temp model) · reverse-polarity & overload protection · 5-year warranty
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100BaseT(X) and 100BaseFX Fast Ethernet |
| IEEE802.3ab | 1000BaseT(X) Ethernet |
| IEEE802.3z | 1000BaseX Ethernet |
| IEEE802.3x | Flow Control |
Switching
| MAC Address Table | 1K |
| Packet Buffer | 1 Mbit |
| Forwarding | Store-and-forward |
Interfaces
| Serial Ports | 2 × RS232/485 (5-pin terminal) |
| 1000Base-X Port | 1000Base-X (fixed), single-mode/multimode optional, SC/ST/FC optional, single/dual fiber optional |
| 1000Base-FX Distance | Multimode 2 km; single-mode 20/40/60/120 km optional |
| LED Indicators | Power, Fiber Port, Serial Port |
Power
| 24V Input | 4-pin terminal, dual redundant input; 24VDC range 12–36VDC |
| 48V Input | 4-pin terminal, dual redundant input; 48VDC range 36–56VDC |
| 220V Input | 4-pin terminal, single power; 220V range 100–240VAC |
| Power Consumption | Max 3 W |
| Power Protection | Reverse-polarity & overload |
Physical
| Housing | IP40 metal enclosure |
| Mounting | DIN-rail (default), desktop/wall-mount optional |
| Dimensions | 120 (W) × 32 (H) × 95 (D) mm |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2 (ESD) Level 3, EN61000-4-3 (RS) Level 3, EN61000-4-4 (EFT) Level 3, EN61000-4-5 (Surge) Level 3, EN61000-4-6 (CS) Level 3, EN61000-4-8 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIC200-1F2S-AC | Industrial protocol converter — 1 × 1000Base-X fixed fiber port (SC/ST/FC, single-mode/multimode, single/dual fiber optional), 2 × RS232/485 serial (5-pin terminal), AC 220V power. | |
| ZJIC200-1F2S-DCL | Industrial protocol converter — 1 × 1000Base-X fixed fiber port (SC/ST/FC, single-mode/multimode, single/dual fiber optional), 2 × RS232/485 serial (5-pin terminal), DC 24V power. | |
| ZJIC200-1F2S-DCH | Industrial protocol converter — 1 × 1000Base-X fixed fiber port (SC/ST/FC, single-mode/multimode, single/dual fiber optional), 2 × RS232/485 serial (5-pin terminal), DC 48V power. |
This page covers all power variants: -AC = AC 220V (100–240V) single input; -DCL = DC 24V (12–36V) redundant dual input; -DCH = DC 48V (36–56V) redundant dual input. The 1000Base-X fiber port is fixed (non-SFP): single-mode or multimode, SC/ST/FC connector, single or dual fiber optional; multimode 2 km, single-mode 20/40/60/120 km. The requested model is ZJIC200-1F2S.
Dimensions

Who uses it, where it goes and how to install it
Written for the ZJIC200-1F2S from its own specifications: 1 × 1000Base-X fixed fiber port to 2 × RS232/485 serial, multimode 2 km or single-mode 20/40/60/120 km, AC 220V or redundant DC 24V/48V, max 3 W.
Who it is for
- Utilities and substations — Carry RS485 meter, RTU or protection-relay data between buildings over fiber, which is not affected by ground potential differences or lightning on long copper runs; the -DCH model runs from a 48V DC station supply.
- Factories with legacy PLCs and drives — Equipment that only has an RS232 or RS485 port can be reached over a fiber link instead of re-cabling copper through noisy areas; 2 serial channels per unit.
- Tunnels, pipelines and traffic systems — Single-mode reach of 20, 40, 60 or 120 km links remote serial sensors, signs or controllers to a control room; the wide-temperature build runs at -40 ~ +75°C in roadside cabinets.
- Integrators commissioning serial links — Besides DIN rail it can sit on a desk or shelf for bench testing, and LEDs for power, fiber and serial port show at a glance whether the link is up.
Where and how to install
- Cabinet mounting — DIN rail is the default; desktop or wall mounting is optional. The unit is 120 × 32 × 95 mm in an IP40 metal housing, so it needs a closed cabinet outdoors. Leave room in front for the fiber bend radius.
- Fiber type and ends — The 1000Base-X port is fixed, not SFP: choose single-mode or multimode, SC/ST/FC and single or dual fiber at order time to match the cable already installed. Both ends of the link must use the same fiber mode and connector type; clean connectors before mating.
- Serial wiring — The 2 serial channels are on a 5-pin terminal. For RS485 use shielded twisted pair, keep A/B polarity consistent, fit 120 Ω termination only at the two ends of the bus, and keep serial cables away from power cables.
- Power wiring — -DCL (12–36VDC) and -DCH (36–56VDC) have dual redundant inputs on a 4-pin terminal: wire two separate DC sources so one failure does not stop the link. -AC takes a single 100–240VAC input. Consumption is max 3 W.
- Temperature, surge and condensation — Standard model -10 ~ +60°C, wide-temperature model -40 ~ +75°C, humidity 5–95% non-condensing. Surge immunity is Level 3 (EN61000-4-5), but serial lines that leave the building still need an external surge protector and a good ground. In humid cabinets use a heater or drain to avoid condensation.
Link planning: pick the power variant and fiber
The three versions differ only in power input. Fiber mode, connector, single/dual fiber and reach are chosen at order time for all of them.
| ZJIC200-1F2S-AC | ZJIC200-1F2S-DCL | ZJIC200-1F2S-DCH | |
|---|---|---|---|
| Power input | 100–240VAC, single | 12–36VDC, dual redundant | 36–56VDC, dual redundant |
| Power consumption | Max 3 W | Max 3 W | Max 3 W |
| Serial ports | 2 × RS232/485 (5-pin) | 2 × RS232/485 (5-pin) | 2 × RS232/485 (5-pin) |
| Fiber port | 1 × 1000Base-X (SC/ST/FC) | 1 × 1000Base-X (SC/ST/FC) | 1 × 1000Base-X (SC/ST/FC) |
| Reach: multimode / single-mode | 2 km / 20, 40, 60, 120 km | 2 km / 20, 40, 60, 120 km | 2 km / 20, 40, 60, 120 km |
| Operating temperature | -10 ~ +60°C (wide -40 ~ +75°C) | -10 ~ +60°C (wide -40 ~ +75°C) | -10 ~ +60°C (wide -40 ~ +75°C) |
| Typical site | Building with mains | 24 V control cabinet | 48 V substation / telecom |
- Pick multimode for links up to 2 km inside a plant, single-mode 20 km for most campus and substation links, and 40, 60 or 120 km only when the measured cable length needs it.
- Pick single fiber when only one spare strand is left in the cable; pick dual fiber when two strands are available.
Values from the ZJIC200-1F2S manufacturer datasheet. Baud rate is not listed in the datasheet.
Fiber-to-Serial Converter FAQ — ZJIC200-1F2S
What does the ZJIC200-1F2S convert?
How far can the fiber link reach?
Which power supply options are available?
Can it work in hot or freezing outdoor cabinets?
How is it mounted and what warranty applies?
Do I need a second ZJIC200-1F2S at the other end of the fiber?
Is the ZJIC200-1F2S transparent to Modbus RTU, and up to what baud rate?
Should I order the ZJIC200-1F2S with single fiber or dual fiber?
How many RS485 devices can I connect to one channel of the ZJIC200-1F2S?
Which ZJIC200-1F2S power version should I choose for a 48V DC substation?
What power connector does the ZJIC200-1F2S have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIC200-1F2S
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.


