ZJIC200-JJ
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIC200-JJ is an industrial fiber media converter chassis built in a standard 2U rack-mount enclosure with 16 card slots for 1-electrical/1-optical Fast Ethernet or Gigabit conversion modules. Each slot accepts mixed 100M and 1000M cards with SC/ST/FC optical connector options and multimode (0.5km/2km) or single-mode (20/40/60/120km) fiber reach. The chassis integrates two independent 220V power inputs for redundancy inside an IP40 metal housing rated -10~60°C standard (-40~75°C wide-temperature cards available), carries CE/FCC/RoHS EMC and EN61000-4 series EMS certification, and ships with a 5-year warranty.
Is This the Right Fit?
Six real deployment scenarios matched to the ZJIC200-JJ chassis's actual datasheet specifications.
- No PoE output on any card slot — cameras/APs still need a separate PoE injector or PoE switch upstream.
- No built-in management interface (Web/SNMP) — per-slot link status cannot be monitored remotely from a NOC.
- Not a desktop or DIN-rail form factor — needs a 19" rack position (480×90×290mm), unsuitable for compact wall-mount cabinets.
Key Features
- 16 card slots for 1-electrical/1-optical Fast Ethernet or Gigabit conversion modules
- Mixed 100M / 1000M card insertion in any slot combination
- SC/ST/FC optical connectors · multimode 0.5/2km or single-mode 20/40/60/120km
- Dual built-in 220V power modules — independent redundant supply
- 2U rack-mount IP40 metal chassis · reverse-polarity & overload protection
- Store-and-forward switching per card · 1K MAC table · 1Mbit buffer
- IEEE 802.3/802.3u/802.3ab/802.3z compliant · CE/FCC/RoHS certified · 5-year warranty
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100Base-T(X) & 100Base-FX Fast Ethernet |
| IEEE802.3ab | 1000Base-T(X) Ethernet |
| IEEE802.3z | 1000Base-X Ethernet |
| IEEE802.3x | Flow Control |
Switching
| MAC Address Table | 1K |
| Packet Buffer | 1 Mbit |
| Forwarding | Store-and-forward |
Interfaces
| RJ45 Port | 1 per card, 100M or Gigabit |
| Fiber Port | 1 fixed per card, 100M or Gigabit, SC/ST/FC selectable |
| Optical Reach | Multimode 0.5km/2km; single-mode 20/40/60/120km selectable |
| LED Indicators | Power, electrical port, optical port |
Power
| 220V Input | Two independent power paths (redundant) |
| Power Consumption | Max 25 W |
| Power Protection | Reverse-polarity & overload |
Physical
| Housing | IP40 metal enclosure |
| Mounting | Rack-mount (2U) |
| Dimensions | 480 (W) × 90 (H) × 290 (D) mm |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2/3/4/5/6 (Level 3), EN61000-4-8 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIC200-JJ | 2U rack-mount chassis, 16 slots, 2 built-in power modules. |
This page covers the ZJIC200-JJ 16-slot chassis itself. 1-electrical/1-optical conversion cards (100M/1000M, SC/ST/FC, multimode/single-mode reach options) are ordered separately according to project requirements.
Dimensions

Who uses it, where it goes and how to plan the links
Written for the ZJIC200-JJ from its own datasheet: 2U 19-inch rack chassis, 16 slots for 1-copper/1-fibre 100M or Gigabit cards, two independent 220 V power inputs, max 25 W, IP40 metal housing.
Who it is for
- CCTV and network integrators with many fibre runs — Up to 16 fibre links from poles, gates or remote buildings end in one 2U rack position at the control room, instead of 16 desktop converters and 16 power adapters on a shelf.
- Campuses, factories and ports upgrading in stages — 100M and Gigabit cards can be mixed in the same chassis, so old Fast Ethernet links keep running while new Gigabit links are added card by card.
- Utilities, telecom rooms and plant control rooms — Two independent 220 V power paths keep all 16 links up if one supply or one circuit fails, and the EMS immunity is EN61000-4-2/3/4/5/6 Level 3 plus EN61000-4-8.
- Projects that mix short and long fibre runs — Each card is ordered with its own optics: multimode 0.5 km or 2 km for in-building runs, single-mode 20/40/60/120 km for links between sites, with SC, ST or FC connectors to match existing patch panels.
Where and how to install
- 19-inch rack, 2U — The chassis is 480 × 90 × 290 mm and is rack-mount only, so plan a 2U position in a 19-inch cabinet at least 290 mm deep plus space behind for power cords. Put it next to the fibre patch panel so jumpers stay short.
- Use both power inputs on different circuits — Redundancy only helps if the two 220 V inputs come from different sources, for example one from the UPS and one from mains or a second UPS. Maximum draw is 25 W, so even a small UPS carries the whole chassis for a long time.
- Match each card to the far end — A card only links to a converter or SFP port of the same speed (100M with 100M, Gigabit with Gigabit), the same fibre mode and compatible wavelength. Label each slot with the remote site name and fibre core numbers.
- Fibre handling — Keep dust caps on unused ports, clean connector end faces before plugging in, and respect the bend radius of jumpers inside the cabinet. Never look into an active fibre port.
- Indoor room, not a bare outdoor cabinet — The housing is IP40 and the standard version runs at -10 to 60°C with 5–95% non-condensing humidity. Use it in an equipment room or a climate-controlled cabinet; for cold or hot cabinets ask for the -40 to 75°C wide-temperature version, and avoid condensation in any case.
- Earthing and surge — Bond the chassis to the rack earth bar. Fibre itself carries no surge, but the copper side of each card does: if a copper port goes to equipment in another building, put an Ethernet surge protector on that run.
Link planning: what the chassis and its cards support
Think of the ZJIC200-JJ as 16 independent media converters sharing one frame and two power supplies. Each card has 1 RJ45 port and 1 fixed fibre port of the same speed; the fibre type and reach are chosen per card when ordering, so one chassis can hold, for example, 10 multimode 2 km cards for the site and 6 single-mode 20 km cards for remote buildings.
| ZJIC200-JJ | |
|---|---|
| Card slots | 16 (100M and 1000M cards can be mixed) |
| Ports per card | 1 × RJ45 + 1 × fixed fibre, 100M or 1000M |
| Fibre connectors | SC / ST / FC (selectable) |
| Multimode reach | 0.5 km / 2 km |
| Single-mode reach | 20 / 40 / 60 / 120 km |
| Switching per card | Store-and-forward, 1K MAC, 1 Mbit buffer |
| Power input / consumption | 2 independent 220 V inputs / max 25 W |
| Operating temperature | -10~60°C standard, -40~75°C wide-temp |
| Housing / mounting / size | IP40 metal / 2U rack / 480 × 90 × 290 mm |
| Management | None listed (LEDs: power, copper, fibre) |
- Pick multimode 0.5 km or 2 km cards for runs inside one building or factory site; pick single-mode 20 km and up for links between buildings or sites.
- Pick the shortest reach class that covers the measured fibre length with some margin; a 120 km card is meant for very long links, not for a 300 m run.
- Pick Gigabit cards for links carrying many cameras; a 100M card limits the whole link to 100 Mbps.
All values are from the ZJIC200-JJ datasheet. The chassis is sold without cards; the 1-copper/1-fibre cards are ordered separately per link.
Media Converter Chassis FAQ — ZJIC200-JJ
What is the ZJIC200-JJ chassis and how many links does it hold?
What fiber reach and connectors do the cards support?
Does it have redundant power?
What are its dimensions and operating conditions?
Which certifications and warranty does it carry?
What do I need at the far end of each ZJIC200-JJ fibre link?
Can I mix multimode and single-mode cards in one ZJIC200-JJ chassis?
Can I monitor the ZJIC200-JJ from the network or replace a card while it is running?
Should I use 100M or Gigabit cards for CCTV links on the ZJIC200-JJ?
Can the ZJIC200-JJ be powered from DC 48 V or installed in an outdoor cabinet?
What power connector does the ZJIC200-JJ have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIC200-JJ
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.