ZJIC200-3
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Overview
The ZJIC200-3 is an industrial fiber media converter that converts 2 × 10/100Base-T (or 10/100/1000Base-T) copper Ethernet to a single fixed 100Base-FX (or 1000Base-X) fiber port, with SC/ST/FC connector and single/dual fiber options. It uses store-and-forward switching with a 1K MAC address table and 1 Mbit packet buffer, and is powered by DC 24V (12–36V) or 48V (36–56V) with redundant dual input, or AC 220V (100–240V), drawing a maximum of 3 W with reverse-polarity and overload protection. Housed in an IP40 metal enclosure with DIN-rail mounting (wall-mount optional), the wide-temperature variant operates from -40 to +75°C and carries a 5-year warranty.
Is This the Right Fit?
Six real deployment scenarios matched to this model's actual datasheet specifications.
- No PoE output — connected cameras or APs on the copper side need their own power source or an external PoE injector.
- Unmanaged, single fixed fiber port per unit — no VLAN/RSTP/ring-network redundancy; not a substitute for a managed ring-topology switch.
- IP40 enclosure only — needs a cabinet or additional protection for direct outdoor rain/dust exposure.
Key Features
- 2 × 10/100Base-T or 10/100/1000Base-T copper ports
- 1 × fixed 100Base-FX or 1000Base-X fiber port — SC/ST/FC, single/dual fiber selectable
- Selectable reach: FX multimode 2 km / single-mode 20–40–60–120 km; GX multimode 0.5–2 km / single-mode 20–40–60–120 km
- DC 24V (12–36V) / 48V (36–56V) redundant dual input, or AC 220V (100–240V)
- IP40 metal enclosure · DIN-rail (default) / wall-mount · compact 32×144×95 mm
- Wide temperature -40 ~ +75°C · reverse-polarity & overload protection · 5-year warranty
Specifications
IEEE Standards
| IEEE802.3 | 10BaseT Ethernet |
| IEEE802.3u | 100Base-T(X) and 100Base-FX Fast Ethernet |
| IEEE802.3ab | 1000Base-T(X) Ethernet |
| IEEE802.3z | 1000Base-X Ethernet |
| IEEE802.3x | Flow Control |
Switching
| MAC Address Table | 1K |
| Packet Buffer | 1 Mbit |
| Forwarding | Store-and-forward |
Interfaces
| RJ45 Ports | 2 × 10/100Base-T or 2 × 10/100/1000Base-T |
| Fiber Port | 1 × fixed 100Base-FX or 1000Base-X, single/multimode, SC/ST/FC, single/dual fiber selectable |
| 100Base-FX Distance | Multimode 2 km; single-mode 20/40/60/120 km selectable |
| 1000Base-X Distance | Multimode 0.5/2 km; single-mode 20/40/60/120 km selectable |
| LED Indicators | Power, Electrical, Optical |
Power
| Terminal | 4-pin terminal |
| DC 24V Input | 4-pin terminal, dual redundant input, range 12–36V DC |
| DC 48V Input | 4-pin terminal, dual redundant input, range 36–56V DC |
| AC 220V Input | 4-pin terminal, single power input, range 100–240V AC |
| Power Consumption | Max 3 W |
| Power Protection | Reverse-polarity & overload |
Physical
| Housing | IP40 metal enclosure |
| Mounting | DIN-rail (default), wall-mount optional |
| Dimensions | 32 (W) × 144 (H) × 95 (D) mm |
Certification
| EMC | CE, FCC |
| EMI | FCC Part 15, EN 55032 (CISPR 32) Class A |
| EMS | EN61000-4-2/3/4/5/6/8 Level 3 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Green | RoHS, WEEE |
Environment
| Standard Temp | -10 ~ +60°C |
| Wide Temp | -40 ~ +75°C |
| Storage Temp | -40 ~ +85°C |
| Humidity | 5–95% non-condensing |
Reliability
| MTBF | 320,000 hours |
| Warranty | 5 years |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| ZJIC200-2T1S-AC | Industrial fiber media converter — 2 × 10/100Base-T, 1 × fixed 100Base-FX (SC/ST/FC), AC 220V (100–240V). | |
| ZJIC200-2T1S-DCL | Industrial fiber media converter — 2 × 10/100Base-T, 1 × fixed 100Base-FX (SC/ST/FC), DC 24V (12–36V), redundant input. | |
| ZJIC200-2T1S-DCH | Industrial fiber media converter — 2 × 10/100Base-T, 1 × fixed 100Base-FX (SC/ST/FC), DC 48V (36–56V), redundant input. | |
| ZJIC200-2GT1F-AC | Industrial fiber media converter — 2 × 10/100/1000Base-T, 1 × fixed 1000Base-X, AC 220V (100–240V). | |
| ZJIC200-2GT1F-DCL | Industrial fiber media converter — 2 × 10/100/1000Base-T, 1 × fixed 1000Base-X, DC 24V (12–36V), redundant input. | |
| ZJIC200-2GT1F-DCH | Industrial fiber media converter — 2 × 10/100/1000Base-T, 1 × fixed 1000Base-X, DC 48V (36–56V), redundant input. |
This page covers the ZJIC200-3 series: -2T1S = 2 × 10/100Base-T + 1 × 100Base-FX fixed fiber; -2GT1F = 2 × 10/100/1000Base-T + 1 × 1000Base-X fixed fiber. Power suffixes: -AC = AC 220V (100–240V); -DCL = DC 24V (12–36V) redundant input; -DCH = DC 48V (36–56V) redundant input. Fiber connector SC/ST/FC and single/dual fiber selectable; 100Base-FX reach: multimode 2 km, single-mode 20/40/60/120 km; 1000Base-X reach: multimode 0.5/2 km, single-mode 20/40/60/120 km. The requested model is ZJIC200-3.
Dimensions

Who uses it, where it goes and how to install it
Written for the ZJIC200-3 series from its own specifications: 2 copper ports (10/100 or 10/100/1000Base-T) plus 1 fixed fiber port (100Base-FX or 1000Base-X), single-mode up to 120 km, DC 24V/48V redundant or AC 220V, max 3 W, DIN rail.
Who it is for
- CCTV installers with two devices per pole — Two cameras, or a camera plus a speaker or access controller, at one remote point share one fiber back to the NVR without a separate small switch in the box.
- Traffic, tunnel and ITS projects — A roadside cabinet with a camera and a controller or sign needs two copper ports; redundant DC 24V/48V input and Level 3 EMC immunity suit tunnel and roadside power.
- Factories and utilities — A PLC and an HMI, or an RTU and a meter gateway, in a remote cabinet reach the control room over one fiber; the 2T1S 100M version is enough for control traffic.
- Integrators who need a local service port — The second RJ45 port can stay free for a technician's laptop during commissioning and maintenance, without unplugging the field device.
Where and how to install
- Enclosure and DIN rail — Clip the 32 × 144 × 95 mm unit on the DIN rail (wall mount optional) inside a closed outdoor box or control cabinet; the IP40 housing is not rain-proof. Leave space below for the fiber patch cord bend.
- Powering the field devices — The two RJ45 ports have no PoE. Put PoE injectors or a DC supply for the cameras in the same box, and keep each copper run to the device within 100 m.
- Converter power — -DCL takes 12–36V DC and -DCH 36–56V DC on dual redundant inputs; wire two independent sources if you have them. -AC takes a single 100–240V AC input. Max 3 W, with reverse-polarity and overload protection.
- Fiber choice and handling — The fiber port is fixed, so specify single-mode or multimode, SC/ST/FC, single or dual fiber and the reach class at order time. Splice the outdoor cable in a splice tray, use a short patch cord to the unit, and clean connectors before mating.
- Grounding, surge and condensation — Ground the box, and fit surge protectors on copper cables and power lines that run up the pole; fiber itself carries no surge. Humidity is rated 5–95% non-condensing, so seal glands and add a drain or heater where nights are cold and humid. Use the -40 ~ +75°C wide-temperature model for sun-exposed boxes.
Link planning: 2T1S (100M) or 2GT1F (gigabit)
Both versions have 2 copper ports and 1 fixed fiber port. The fiber speed decides how much traffic one link carries and which unit you need at the other end.
| 2T1S · 100M | 2GT1F · Gigabit | |
|---|---|---|
| Copper ports | 2 × 10/100Base-T | 2 × 10/100/1000Base-T |
| Fiber port | 1 × 100Base-FX (fixed) | 1 × 1000Base-X (fixed) |
| Multimode reach | 2 km | 0.5 / 2 km |
| Single-mode reach | 20 / 40 / 60 / 120 km | 20 / 40 / 60 / 120 km |
| Fiber-side throughput (8 Mbps cameras, ≤70% load) | ≈ 8 | ≈ 87 |
| Matching unit at the other end | ZJIC200-3 2T1S or ZJIC200-2 1T1S | ZJIC200-3 2GT1F or ZJIC200-2 1GT1F |
| Power models | -AC / -DCL / -DCH | -AC / -DCL / -DCH |
| Power consumption | Max 3 W | Max 3 W |
- Pick 2T1S for two cameras or a PLC and HMI at one point: two 8 Mbps cameras use about 16 Mbps of the 100M fiber.
- Pick 2GT1F when a small switch with more cameras is plugged into one of the copper ports, or the link is a backbone between two buildings.
Ports, reach and power are from the ZJIC200-3 manufacturer datasheet. Camera counts assume 8 Mbps per camera and at most 70% of the fiber speed (70 ÷ 8 and 700 ÷ 8, rounded down). The ZJIC200-2 pairing is by matching fiber standard.
Industrial Fiber Media Converter FAQ — ZJIC200-3
How far can the ZJIC200-3 transmit over fiber?
What power input does the ZJIC200-3 accept?
Can it run inside hot outdoor cabinets?
How is the ZJIC200-3 mounted?
Is the ZJIC200-3 Fast Ethernet or gigabit?
Can I uplink IP cameras and PLCs through it?
Can a ZJIC200-3 at the camera end pair with a ZJIC200-2 or a switch SFP port at the control room?
Do the two copper ports of the ZJIC200-3 work like a small switch?
Can I daisy-chain several ZJIC200-3 units along a road or build a fiber ring?
The fiber LED on my ZJIC200-3 stays off. What should I check?
For the gigabit ZJIC200-2GT1F on multimode, should I choose 0.5 km or 2 km?
What power connector does the ZJIC200-3 have, and do I need to confirm it before ordering?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA
Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZJIC200-3
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.