S4G02GFI-SFP
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Not sure about the PoE budget? Size it with the calculator →
Need the PDF datasheet? Get it on WhatsApp →Overview
The S4G02GFI-SFP is the fibre-uplink member of the 4-port PoE family: four 10/100/1000M PoE ports for cameras, access points or intercoms, and two 1000M SFP slots instead of copper uplinks. Copper tops out at 100 m per segment, so when the switch sits at a gate house, a pump station or the far end of a yard while the recorder is in the office block, the SFP pair carries the traffic over fibre — single-mode modules cover tens of kilometres. Total PoE budget is 52 W with 30 W available on any single port, the housing is fanless metal, and the unit is unmanaged: power it, plug in, done.
Is This the Right Fit?
Six real deployment scenarios matched to this model's actual datasheet specifications.
- Unmanaged Layer 2 only — no VLAN segmentation or STP/RSTP; choose a managed switch if network isolation or spanning tree is required.
- No ring/loop redundancy protocol — wire in star, tree or bus topology only; do not create physical wiring loops between ports.
- Commercial-grade -10 to +70°C housing in a compact desktop/wall-mount form factor — not rated for industrial wide-temperature extremes and not rack-mountable without accessories.
Key Features
- 4 x 10/100M PoE ports, IEEE802.3af/at, up to 30W per port with smart PD detection
- 2 x 10/100M uplink ports to NVR or router
- Extend mode: PoE + data reach up to 250m (link rate steps down to 10Mbps)
- No extra power cable to the camera — PoE carries power and data on one cable, cutting install cost
- Fanless metal housing — silent operation, no moving parts to fail
- Built-in watchdog auto-reset keeps the switch stable under heavy camera loads
- Store-and-forward switching with flow control, auto-negotiation and auto MDI/MDIX
Specifications
IEEE Standards
| IEEE802.3 | 10Base-T Ethernet |
| IEEE802.3u | 100Base-TX Fast Ethernet |
| IEEE802.3x | Flow Control |
| IEEE802.3af | PoE |
| IEEE802.3at | PoE+ |
Switching
| Switching Capacity | 16 Gbps |
| Forwarding Rate | 11.904 Mpps |
| MAC Address Table | 4K |
| Flow Control | Supported (IEEE 802.3x) |
| Auto MDI/MDI-X | Supported |
Interfaces
| PoE Ports | 4 × 10/100/1000Base-T (RJ45), IEEE 802.3af/at |
| Uplink | 2 × 1000Base-X SFP slots (modules ordered separately) |
| Fibre Reach | Depends on SFP module — multimode ~550 m, single-mode 20 / 40 / 60 / 120 km options |
| Switching Mode | Store-and-forward |
| LED Indicators | PWR (power), red (PoE status), blue (link/activity) |
PoE
| PoE Standard | IEEE802.3af / IEEE802.3at |
| PoE Ports | 4 |
| Max Power per Port | 30W |
| Powered Device Detection | Automatic, smart detection — will not damage non-PoE devices |
| PoE Mode | Mode A (power over data pairs) |
| Cable Distance | Standard 100 m per copper segment; use the SFP uplinks for longer runs |
Power
| Input Voltage | AC 100–240 V |
| Power Supply | Built-in power supply, DC 52V 1A |
| Total Power Consumption | < 52 W at full load |
| Protection | Reverse-polarity and overload protection |
Physical
| Dimensions | 145.8 × 114.2 × 36 mm (excluding protrusions) |
| Housing | Metal, fanless |
| Cooling | Fanless (0 fans) |
| Protection Rating | IP30 |
| Mounting | Desktop or wall-mount |
Environment
| Operating / Storage Temperature | -10°C ~ +70°C |
| Humidity | 5%–95% RH, non-condensing |
| Protection Rating | IP30 |
| MTBF | 50,000 hours (manufacturer figure) |
Package
| Units per Carton | 50 units/carton |
| Packing Dimensions | 195 × 164 × 44 mm |
| Unit Weight | 0.6 kg per unit |
| Box Contents | Switch × 1, power cord × 1, manual × 1, certificate × 1, warranty card × 1 |
Models & Ordering
| Model | Product Description | Price |
|---|---|---|
| S4G02GFI-SFP | 4 × 10/100/1000M PoE ports (IEEE 802.3af/at, 30 W per port) + 2 × 1000M SFP fibre uplink slots. 52 W total PoE budget, switching capacity 16 Gbps, MAC table 4K, 145.8 × 114.2 × 36 mm, built-in DC 52V 1A supply. SFP modules are ordered separately to match fibre type and distance. | Get Quote |
Single model, single 52 W PoE budget. It shares housing and PoE behaviour with the copper S4G02GI; the difference is the uplink — two 1000M SFP fibre slots instead of two copper Gigabit ports. Choose this version when the run back to the recorder or router is longer than 100 m.
Dimensions

Who uses it, where it goes and how to install it
Written for the S4G02GFI-SFP from its own specifications: 4 × 10/100/1000M PoE ports, 2 × 1000M SFP fibre uplinks, 52 W PoE budget, 30 W per port, fanless IP30 metal case.
Who it is for
- Installers with a camera point beyond 100 m — A gate house, pump station or far corner of a yard with up to 4 cameras: the switch powers them locally and sends the video back over fibre, where copper would stop at 100 m.
- Integrators linking several small buildings — With 2 SFP slots, one fibre comes in from the office and the second continues to the next building, so farms, schools or warehouses can be chained without a separate fibre switch at each stop.
- Sites with lightning or long outdoor links — Fibre carries no electricity, so the building-to-building link cannot bring a surge or ground-potential difference into the recorder room the way a long copper run can.
- Distributors wanting their own brand — The S4G02GFI-SFP is an Atlas factory-direct model: neutral casing ready for your logo, custom port/power options and small batches, as stated on this page.
Where and how to install
- Indoor or in a sealed cabinet — The case is IP30: fine on a desk, shelf or wall indoors, but outdoors it must go inside a weatherproof cabinet. At 145.8 × 114.2 × 36 mm it fits small pole or wall boxes; leave room for the fibre bend and the LC patch leads.
- Heat, sun and condensation — It is fanless and rated -10 to +70°C, 5–95% RH non-condensing. A metal box in full sun runs far hotter than the air, so shade it, vent it and keep it away from the power supply; in humid sites add a breather or desiccant so water does not condense on the board.
- Fibre side — SFP modules are ordered separately: choose multimode for up to ~550 m or single-mode for the 20 / 40 / 60 / 120 km options, and the module at the far end must match. Terminate the cable in a small fibre box, keep dust caps on unused ports and do not bend patch leads tightly.
- Camera side: copper runs — Keep each camera run to 100 m of solid-copper Cat5e or Cat6; copper-clad aluminium cable drops voltage and can leave a camera unpowered. Put outdoor cable joints in a junction box.
- Surge, earthing and mains power — No surge rating is listed, so on pole cameras or long outdoor copper runs fit Ethernet surge protectors and earth the cabinet. The input is AC 100–240 V, so it runs directly on 110/127 V or 220/240 V mains, and a small UPS keeps the remote point recording through outages.
PoE budget: how many cameras
52 W is shared by the 4 ports and any single port can take up to 30 W. Four ordinary IR cameras use less than half of it; the limit appears with PTZ or heavy-IR cameras. The built-in supply is DC 52V 1A, so plan to leave some reserve rather than load the full 52 W.
| S4G02GFI-SFP | |
|---|---|
| PoE ports / uplinks | 4 × 10/100/1000M PoE / 2 × 1000M SFP |
| Total PoE budget | 52 W |
| Max. power on one port | 30 W |
| Fixed IR cameras at 6 W each | 4 (24 W) |
| Small PTZ / heavy-IR cameras at 13 W, keeping 20% reserve | 3 (39 W) |
| 30 W devices at full load | 1 (+ 22 W) |
| Mixed example | 1 × 13 W + 3 × 6 W = 31 W |
| Copper cable per port | 100 m |
| Uplink to NVR / core | SFP: ~550 m MM / 20–120 km SM |
| Operating temperature | -10 ~ +70°C |
- Pick the S4G02GFI-SFP when the 4 cameras are more than 100 m from the recorder: fibre replaces the long copper run.
- If the recorder is within 100 m, the copper-uplink S4G02GI does the same job without SFP modules.
- More than 4 cameras at the remote point: step up to the S802GIGFI (8 PoE + 1 SFP) or S8G02G2GFI (8 PoE + 2 SFP).
Camera counts assume typical draws of 6 W (fixed IR camera) and 13 W (small PTZ or heavy-IR camera); check the maximum power on each camera's own datasheet. Fibre reach depends on the SFP module.
4-Port Gigabit PoE Switch FAQ — S4G02GFI-SFP
How many cameras can the S4G02GFI-SFP power?
How far can the fiber uplinks reach?
When should I pick this model over a copper-uplink switch?
Does it need any configuration to start working?
What about housing, power input and operating conditions?
Which SFP modules do I need for the S4G02GFI-SFP, and what goes at the other end of the fibre?
The S4G02GFI-SFP has no copper uplink: how do I connect a local NVR, router or laptop?
Is the 52 W on the S4G02GFI-SFP per port or shared, and can it run a 30 W PTZ?
Does the S4G02GFI-SFP have the 250 m extend mode for a camera beyond 100 m?
Can I chain several buildings with the two SFP slots of the S4G02GFI-SFP?
Will the S4G02GFI-SFP power Hikvision, Dahua, Uniview or other brands of IP camera?
Ordering questions — samples, shipping, payment, lead time and genuine stock — are answered once on our FAQ page.
Related Products








Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: S4G02GFI-SFP
For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.